Files
vuln-cve/data/2017/14xxx/CVE-2017-14464.json
T

168 lines
7.6 KiB
JSON

{
"containers": {
"cna": {
"affected": [
{
"product": "Allen Bradley",
"vendor": "Talos",
"versions": [
{
"status": "affected",
"version": "Allen Bradley Micrologix 1400 Series B FRN 21.2, Allen Bradley Micrologix 1400 Series B FRN 21.0, Allen Bradley Micrologix 1400 Series B FRN 15"
}
]
}
],
"datePublic": "2018-03-28T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability.Required Keyswitch State: REMOTE or PROG Associated Fault Code: 0001 Fault Type: Non-User Description: A fault state can be triggered by setting the NVRAM/memory module user program mismatch bit (S2:9) when a memory module is NOT installed."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "denial of service",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-19T18:21:13.000Z",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2017-0443"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "talos-cna@cisco.com",
"DATE_PUBLIC": "2018-03-28T00:00:00",
"ID": "CVE-2017-14464",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Allen Bradley",
"version": {
"version_data": [
{
"version_value": "Allen Bradley Micrologix 1400 Series B FRN 21.2, Allen Bradley Micrologix 1400 Series B FRN 21.0, Allen Bradley Micrologix 1400 Series B FRN 15"
}
]
}
}
]
},
"vendor_name": "Talos"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability.Required Keyswitch State: REMOTE or PROG Associated Fault Code: 0001 Fault Type: Non-User Description: A fault state can be triggered by setting the NVRAM/memory module user program mismatch bit (S2:9) when a memory module is NOT installed."
}
]
},
"impact": {
"cvss": {
"baseScore": 10,
"baseSeverity": null,
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "denial of service"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2017-0443",
"refsource": "MISC",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2017-0443"
}
]
}
}
},
"adp": [
{
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2024-08-05T19:27:40.681Z"
},
"title": "CVE Program Container",
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2017-0443"
}
]
}
]
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2017-14464",
"datePublished": "2018-04-05T21:00:00.000Z",
"dateReserved": "2017-09-13T00:00:00.000Z",
"dateUpdated": "2024-09-16T21:57:12.189Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}