Files
vuln-cve/data/2023/39xxx/CVE-2023-39167.json
T

158 lines
5.6 KiB
JSON
Raw Blame History

This file contains invisible Unicode characters
This file contains invisible Unicode characters that are indistinguishable to humans but may be processed differently by a computer. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
{
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"cveMetadata": {
"cveId": "CVE-2023-39167",
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"state": "PUBLISHED",
"assignerShortName": "CERTVDE",
"dateReserved": "2023-07-25T14:06:01.343Z",
"datePublished": "2023-12-07T14:05:01.746Z",
"dateUpdated": "2025-11-04T19:17:34.708Z"
},
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Storage Box V1",
"vendor": "SENEC",
"versions": [
{
"status": "affected",
"version": "all (until 19.06.2023)"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Storage Box V2",
"vendor": "SENEC",
"versions": [
{
"status": "affected",
"version": "all (until 19.06.2023)"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Storage Box V3",
"vendor": "SENEC",
"versions": [
{
"status": "affected",
"version": "all (until 19.06.2023)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Ph0s[4]"
},
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "R0ckE7"
}
],
"datePublic": "2023-12-07T14:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In SENEC Storage Box V1,V2 and V3 an unauthenticated remote attacker can obtain the devices' logfiles that contain sensitive data."
}
],
"value": "In SENEC Storage Box V1,V2 and V3 an unauthenticated remote attacker can obtain the devices' logfiles that contain sensitive data."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-862",
"description": "CWE-862 Missing Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE",
"dateUpdated": "2023-12-14T14:35:53.018Z"
},
"references": [
{
"url": "https://seclists.org/fulldisclosure/2023/Nov/5"
}
],
"source": {
"defect": [
"CERT@VDE#64567"
],
"discovery": "EXTERNAL"
},
"title": "SENEC: Storage Box V1,V2 and V3 affected by improper access control vulnerability",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
},
"adp": [
{
"title": "CVE Program Container",
"references": [
{
"url": "https://seclists.org/fulldisclosure/2023/Nov/5",
"tags": [
"x_transferred"
]
},
{
"url": "http://seclists.org/fulldisclosure/2023/Nov/10"
}
],
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2025-11-04T19:17:34.708Z"
}
}
]
}
}