"affected": [
{
"product": "CP-8000 MASTER MODULE WITH I/O -25/+70°C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions < V16.20"
}
]
},
{
"product": "CP-8000 MASTER MODULE WITH I/O -40/+70°C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions < V16.20"
}
]
},
{
"product": "CP-8021 MASTER MODULE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions < V16.20"
}
]
},
{
"product": "CP-8022 MASTER MODULE WITH GPRS",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions < V16.20"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions < V16.20), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions < V16.20), CP-8021 MASTER MODULE (All versions < V16.20), CP-8022 MASTER MODULE WITH GPRS (All versions < V16.20). An undocumented debug port uses hard-coded default credentials. If this port is enabled by a privileged user, an attacker aware of the credentials could access an administrative debug shell on the affected device."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798: Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-01-11T11:27:17.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-324998.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-45033",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "CP-8000 MASTER MODULE WITH I/O -25/+70°C",
"version": {
"version_data": [
{
"version_value": "All versions < V16.20"
}
]
}
},
{
"product_name": "CP-8000 MASTER MODULE WITH I/O -40/+70°C",
"version": {
"version_data": [
{
"version_value": "All versions < V16.20"
}
]
}
},
{
"product_name": "CP-8021 MASTER MODULE",
"version": {
"version_data": [
{
"version_value": "All versions < V16.20"
}
]
}
},
{
"product_name": "CP-8022 MASTER MODULE WITH GPRS",
"version": {
"version_data": [
{
"version_value": "All versions < V16.20"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions < V16.20), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions < V16.20), CP-8021 MASTER MODULE (All versions < V16.20), CP-8022 MASTER MODULE WITH GPRS (All versions < V16.20). An undocumented debug port uses hard-coded default credentials. If this port is enabled by a privileged user, an attacker aware of the credentials could access an administrative debug shell on the affected device."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-798: Use of Hard-coded Credentials"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-324998.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-324998.pdf"
}
]
}
}
},
"adp": [
{
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2024-08-04T04:32:13.621Z"
},
"title": "CVE Program Container",
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-324998.pdf"
}
]
}
]
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-45033",
"datePublished": "2022-01-11T11:27:17.000Z",
"dateReserved": "2021-12-13T00:00:00.000Z",
"dateUpdated": "2024-08-04T04:32:13.621Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}