227 lines
8.8 KiB
JSON
227 lines
8.8 KiB
JSON
{
|
|
"containers": {
|
|
"cna": {
|
|
"affected": [
|
|
{
|
|
"product": "VideoEdge",
|
|
"vendor": "Johnson Controls",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "5.4.1 to 5.7.1"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"datePublic": "2022-01-11T00:00:00.000Z",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Running a vulnerability scanner against VideoEdge NVRs can cause some functionality to stop."
|
|
}
|
|
],
|
|
"metrics": [
|
|
{
|
|
"cvssV3_1": {
|
|
"attackComplexity": "LOW",
|
|
"attackVector": "NETWORK",
|
|
"availabilityImpact": "LOW",
|
|
"baseScore": 5.3,
|
|
"baseSeverity": "MEDIUM",
|
|
"confidentialityImpact": "NONE",
|
|
"integrityImpact": "NONE",
|
|
"privilegesRequired": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"userInteraction": "NONE",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
|
|
"version": "3.1"
|
|
}
|
|
}
|
|
],
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"cweId": "CWE-228",
|
|
"description": "CWE-228: Improper Handling of Syntactically Invalid Structure",
|
|
"lang": "en",
|
|
"type": "CWE"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"providerMetadata": {
|
|
"dateUpdated": "2022-01-14T19:10:42.000Z",
|
|
"orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
|
|
"shortName": "jci"
|
|
},
|
|
"references": [
|
|
{
|
|
"tags": [
|
|
"x_refsource_CONFIRM"
|
|
],
|
|
"url": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories"
|
|
},
|
|
{
|
|
"name": "ICS-CERT Advisory",
|
|
"tags": [
|
|
"third-party-advisory",
|
|
"x_refsource_CERT"
|
|
],
|
|
"url": "https://us-cert.gov/ics/advisories/ICSA-22-011-01"
|
|
}
|
|
],
|
|
"solutions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Update VideoEdge with hot fix for versions 5.4.1 to 5.7.1 or upgrade VideoEdge to version 5.9."
|
|
}
|
|
],
|
|
"source": {
|
|
"discovery": "EXTERNAL"
|
|
},
|
|
"title": "VideoEdge",
|
|
"x_generator": {
|
|
"engine": "Vulnogram 0.0.9"
|
|
},
|
|
"x_legacyV4Record": {
|
|
"CVE_data_meta": {
|
|
"ASSIGNER": "productsecurity@jci.com",
|
|
"DATE_PUBLIC": "2022-01-11T19:30:00.000Z",
|
|
"ID": "CVE-2021-36199",
|
|
"STATE": "PUBLIC",
|
|
"TITLE": "VideoEdge"
|
|
},
|
|
"affects": {
|
|
"vendor": {
|
|
"vendor_data": [
|
|
{
|
|
"product": {
|
|
"product_data": [
|
|
{
|
|
"product_name": "VideoEdge",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "=",
|
|
"version_name": "5.4.1 to 5.7.1",
|
|
"version_value": "5.4.1 to 5.7.1"
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
},
|
|
"vendor_name": "Johnson Controls"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
"data_format": "MITRE",
|
|
"data_type": "CVE",
|
|
"data_version": "4.0",
|
|
"description": {
|
|
"description_data": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "Running a vulnerability scanner against VideoEdge NVRs can cause some functionality to stop."
|
|
}
|
|
]
|
|
},
|
|
"generator": {
|
|
"engine": "Vulnogram 0.0.9"
|
|
},
|
|
"impact": {
|
|
"cvss": {
|
|
"attackComplexity": "LOW",
|
|
"attackVector": "NETWORK",
|
|
"availabilityImpact": "LOW",
|
|
"baseScore": 5.3,
|
|
"baseSeverity": "MEDIUM",
|
|
"confidentialityImpact": "NONE",
|
|
"integrityImpact": "NONE",
|
|
"privilegesRequired": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"userInteraction": "NONE",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
|
|
"version": "3.1"
|
|
}
|
|
},
|
|
"problemtype": {
|
|
"problemtype_data": [
|
|
{
|
|
"description": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "CWE-228: Improper Handling of Syntactically Invalid Structure"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"references": {
|
|
"reference_data": [
|
|
{
|
|
"name": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories",
|
|
"refsource": "CONFIRM",
|
|
"url": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories"
|
|
},
|
|
{
|
|
"name": "ICS-CERT Advisory",
|
|
"refsource": "CERT",
|
|
"url": "https://us-cert.gov/ics/advisories/ICSA-22-011-01"
|
|
}
|
|
]
|
|
},
|
|
"solution": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Update VideoEdge with hot fix for versions 5.4.1 to 5.7.1 or upgrade VideoEdge to version 5.9."
|
|
}
|
|
],
|
|
"source": {
|
|
"discovery": "EXTERNAL"
|
|
}
|
|
}
|
|
},
|
|
"adp": [
|
|
{
|
|
"providerMetadata": {
|
|
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"shortName": "CVE",
|
|
"dateUpdated": "2024-08-04T00:54:50.683Z"
|
|
},
|
|
"title": "CVE Program Container",
|
|
"references": [
|
|
{
|
|
"tags": [
|
|
"x_refsource_CONFIRM",
|
|
"x_transferred"
|
|
],
|
|
"url": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories"
|
|
},
|
|
{
|
|
"name": "ICS-CERT Advisory",
|
|
"tags": [
|
|
"third-party-advisory",
|
|
"x_refsource_CERT",
|
|
"x_transferred"
|
|
],
|
|
"url": "https://us-cert.gov/ics/advisories/ICSA-22-011-01"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"cveMetadata": {
|
|
"assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
|
|
"assignerShortName": "jci",
|
|
"cveId": "CVE-2021-36199",
|
|
"datePublished": "2022-01-14T19:10:42.869Z",
|
|
"dateReserved": "2021-07-06T00:00:00.000Z",
|
|
"dateUpdated": "2024-09-16T18:44:18.470Z",
|
|
"state": "PUBLISHED"
|
|
},
|
|
"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.1"
|
|
} |