168 lines
6.2 KiB
JSON
168 lines
6.2 KiB
JSON
{
|
|
"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.1",
|
|
"cveMetadata": {
|
|
"cveId": "CVE-2021-34577",
|
|
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
|
|
"state": "PUBLISHED",
|
|
"assignerShortName": "CERTVDE",
|
|
"requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
|
|
"dateReserved": "2021-06-10T19:19:08.025Z",
|
|
"datePublished": "2022-11-09T16:11:03.018Z",
|
|
"dateUpdated": "2025-05-01T19:16:45.077Z"
|
|
},
|
|
"containers": {
|
|
"cna": {
|
|
"affected": [
|
|
{
|
|
"defaultStatus": "affected",
|
|
"product": "PICOFLUX AiR",
|
|
"vendor": "Kaden",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"credits": [
|
|
{
|
|
"lang": "en",
|
|
"type": "finder",
|
|
"user": "00000000-0000-4000-9000-000000000000",
|
|
"value": "Libor POLČÁK reported to CERT@VDE"
|
|
}
|
|
],
|
|
"datePublic": "2021-09-16T10:00:00.000Z",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"supportingMedia": [
|
|
{
|
|
"base64": false,
|
|
"type": "text/html",
|
|
"value": "In the Kaden PICOFLUX AiR water meter an adversary can read the values through wireless M-Bus mode 5 with a hardcoded shared key while being adjacent to the device."
|
|
}
|
|
],
|
|
"value": "In the Kaden PICOFLUX AiR water meter an adversary can read the values through wireless M-Bus mode 5 with a hardcoded shared key while being adjacent to the device."
|
|
}
|
|
],
|
|
"impacts": [
|
|
{
|
|
"capecId": "CAPEC-21",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CAPEC-21 Exploitation of Trusted Credentials"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"metrics": [
|
|
{
|
|
"cvssV3_1": {
|
|
"attackComplexity": "LOW",
|
|
"attackVector": "ADJACENT_NETWORK",
|
|
"availabilityImpact": "NONE",
|
|
"baseScore": 6.5,
|
|
"baseSeverity": "MEDIUM",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "NONE",
|
|
"privilegesRequired": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"userInteraction": "NONE",
|
|
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
|
|
"version": "3.1"
|
|
},
|
|
"format": "CVSS",
|
|
"scenarios": [
|
|
{
|
|
"lang": "en",
|
|
"value": "GENERAL"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"cweId": "CWE-798",
|
|
"description": "CWE-798 Use of Hard-coded Credentials",
|
|
"lang": "en",
|
|
"type": "CWE"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"providerMetadata": {
|
|
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
|
|
"shortName": "CERTVDE",
|
|
"dateUpdated": "2022-11-09T16:11:03.018Z"
|
|
},
|
|
"references": [
|
|
{
|
|
"url": "https://www.fit.vutbr.cz/~polcak/CVE-2021-34577"
|
|
}
|
|
],
|
|
"source": {
|
|
"discovery": "EXTERNAL"
|
|
},
|
|
"title": "Hardcoded credentials in Kaden PICOFLUX AiR",
|
|
"x_generator": {
|
|
"engine": "Vulnogram 0.1.0-dev"
|
|
}
|
|
},
|
|
"adp": [
|
|
{
|
|
"providerMetadata": {
|
|
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"shortName": "CVE",
|
|
"dateUpdated": "2024-08-04T00:19:46.586Z"
|
|
},
|
|
"title": "CVE Program Container",
|
|
"references": [
|
|
{
|
|
"url": "https://www.fit.vutbr.cz/~polcak/CVE-2021-34577",
|
|
"tags": [
|
|
"x_transferred"
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"metrics": [
|
|
{
|
|
"other": {
|
|
"type": "ssvc",
|
|
"content": {
|
|
"timestamp": "2025-05-01T19:16:21.657086Z",
|
|
"id": "CVE-2021-34577",
|
|
"options": [
|
|
{
|
|
"Exploitation": "none"
|
|
},
|
|
{
|
|
"Automatable": "no"
|
|
},
|
|
{
|
|
"Technical Impact": "partial"
|
|
}
|
|
],
|
|
"role": "CISA Coordinator",
|
|
"version": "2.0.3"
|
|
}
|
|
}
|
|
}
|
|
],
|
|
"title": "CISA ADP Vulnrichment",
|
|
"providerMetadata": {
|
|
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
|
"shortName": "CISA-ADP",
|
|
"dateUpdated": "2025-05-01T19:16:45.077Z"
|
|
}
|
|
}
|
|
]
|
|
}
|
|
} |