"affected": [
|
|
{
|
|
"product": "Robot Controller MELFA FR Series; Robot Controller CR Series; Cooperative Robot ASSISTA",
|
|
"vendor": "n/a",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "Controller \"CR800-*V*D\" of RV-*FR***-D-* all versions, Controller \"CR800-*HD\" of RH-*FRH***-D-* all versions, Controller \"CR800-*HRD\" of RH-*FRHR***-D-* all versions, Controller \"CR800-*V*R with R16RTCPU\" of RV-*FR***-R-* all versions, Controller \"CR800-*HR with R16RTCPU\" of RH-*FRH***-R-* all versions, Controller \"CR800-*HRR with R16RTCPU\" of RH-*FRHR***-R-* all versions, Controller \"CR800-*V*Q with Q172DSRCPU\" of RV-*FR***-Q-* all versions, Controller \"CR800-*HQ with Q172DSRCPU\" of RH-*FRH***-Q-* all versions, Controller \"CR800-*HRQ with Q172DSRCPU\" of RH-*FRHR***-Q-* all versions"
|
|
},
|
|
{
|
|
"status": "affected",
|
|
"version": "Controller \"CR800-CVD\" of RV-8CRL-D-* all versions, Controller \"CR800-CHD\" of RH-*CRH**-D-* all versions"
|
|
},
|
|
{
|
|
"status": "affected",
|
|
"version": "Controller \"CR800-05VD\" of RV-5AS-D-* all versions"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Resource management errors vulnerability in a robot controller of MELFA FR Series(controller \"CR800-*V*D\" of RV-*FR***-D-* all versions, controller \"CR800-*HD\" of RH-*FRH***-D-* all versions, controller \"CR800-*HRD\" of RH-*FRHR***-D-* all versions, controller \"CR800-*V*R with R16RTCPU\" of RV-*FR***-R-* all versions, controller \"CR800-*HR with R16RTCPU\" of RH-*FRH***-R-* all versions, controller \"CR800-*HRR with R16RTCPU\" of RH-*FRHR***-R-* all versions, controller \"CR800-*V*Q with Q172DSRCPU\" of RV-*FR***-Q-* all versions, controller \"CR800-*HQ with Q172DSRCPU\" of RH-*FRH***-Q-* all versions, controller \"CR800-*HRQ with Q172DSRCPU\" of RH-*FRHR***-Q-* all versions) and a robot controller of MELFA CR Series(controller \"CR800-CVD\" of RV-8CRL-D-* all versions, controller \"CR800-CHD\" of RH-*CRH**-D-* all versions) as well as a cooperative robot ASSISTA(controller \"CR800-05VD\" of RV-5AS-D-* all versions) allows a remote unauthenticated attacker to cause a DoS of the execution of the robot program and the Ethernet communication by sending a large amount of packets in burst over a short period of time. As a result of DoS, an error may occur. A reset is required to recover it if the error occurs."
|
|
}
|
|
],
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"description": "Resource management errors",
|
|
"lang": "en",
|
|
"type": "text"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"providerMetadata": {
|
|
"dateUpdated": "2021-01-29T14:54:32.000Z",
|
|
"orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
|
|
"shortName": "Mitsubishi"
|
|
},
|
|
"references": [
|
|
{
|
|
"tags": [
|
|
"x_refsource_MISC"
|
|
],
|
|
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-019_en.pdf"
|
|
}
|
|
],
|
|
"x_legacyV4Record": {
|
|
"CVE_data_meta": {
|
|
"ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
|
|
"ID": "CVE-2021-20586",
|
|
"STATE": "PUBLIC"
|
|
},
|
|
"affects": {
|
|
"vendor": {
|
|
"vendor_data": [
|
|
{
|
|
"product": {
|
|
"product_data": [
|
|
{
|
|
"product_name": "Robot Controller MELFA FR Series; Robot Controller CR Series; Cooperative Robot ASSISTA",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_value": "Controller \"CR800-*V*D\" of RV-*FR***-D-* all versions, Controller \"CR800-*HD\" of RH-*FRH***-D-* all versions, Controller \"CR800-*HRD\" of RH-*FRHR***-D-* all versions, Controller \"CR800-*V*R with R16RTCPU\" of RV-*FR***-R-* all versions, Controller \"CR800-*HR with R16RTCPU\" of RH-*FRH***-R-* all versions, Controller \"CR800-*HRR with R16RTCPU\" of RH-*FRHR***-R-* all versions, Controller \"CR800-*V*Q with Q172DSRCPU\" of RV-*FR***-Q-* all versions, Controller \"CR800-*HQ with Q172DSRCPU\" of RH-*FRH***-Q-* all versions, Controller \"CR800-*HRQ with Q172DSRCPU\" of RH-*FRHR***-Q-* all versions"
|
|
},
|
|
{
|
|
"version_value": "Controller \"CR800-CVD\" of RV-8CRL-D-* all versions, Controller \"CR800-CHD\" of RH-*CRH**-D-* all versions"
|
|
},
|
|
{
|
|
"version_value": "Controller \"CR800-05VD\" of RV-5AS-D-* all versions"
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
},
|
|
"vendor_name": "n/a"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
"data_format": "MITRE",
|
|
"data_type": "CVE",
|
|
"data_version": "4.0",
|
|
"description": {
|
|
"description_data": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "Resource management errors vulnerability in a robot controller of MELFA FR Series(controller \"CR800-*V*D\" of RV-*FR***-D-* all versions, controller \"CR800-*HD\" of RH-*FRH***-D-* all versions, controller \"CR800-*HRD\" of RH-*FRHR***-D-* all versions, controller \"CR800-*V*R with R16RTCPU\" of RV-*FR***-R-* all versions, controller \"CR800-*HR with R16RTCPU\" of RH-*FRH***-R-* all versions, controller \"CR800-*HRR with R16RTCPU\" of RH-*FRHR***-R-* all versions, controller \"CR800-*V*Q with Q172DSRCPU\" of RV-*FR***-Q-* all versions, controller \"CR800-*HQ with Q172DSRCPU\" of RH-*FRH***-Q-* all versions, controller \"CR800-*HRQ with Q172DSRCPU\" of RH-*FRHR***-Q-* all versions) and a robot controller of MELFA CR Series(controller \"CR800-CVD\" of RV-8CRL-D-* all versions, controller \"CR800-CHD\" of RH-*CRH**-D-* all versions) as well as a cooperative robot ASSISTA(controller \"CR800-05VD\" of RV-5AS-D-* all versions) allows a remote unauthenticated attacker to cause a DoS of the execution of the robot program and the Ethernet communication by sending a large amount of packets in burst over a short period of time. As a result of DoS, an error may occur. A reset is required to recover it if the error occurs."
|
|
}
|
|
]
|
|
},
|
|
"problemtype": {
|
|
"problemtype_data": [
|
|
{
|
|
"description": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "Resource management errors"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"references": {
|
|
"reference_data": [
|
|
{
|
|
"name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-019_en.pdf",
|
|
"refsource": "MISC",
|
|
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-019_en.pdf"
|
|
}
|
|
]
|
|
}
|
|
}
|
|
},
|
|
"adp": [
|
|
{
|
|
"providerMetadata": {
|
|
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"shortName": "CVE",
|
|
"dateUpdated": "2024-08-03T17:45:44.779Z"
|
|
},
|
|
"title": "CVE Program Container",
|
|
"references": [
|
|
{
|
|
"tags": [
|
|
"x_refsource_MISC",
|
|
"x_transferred"
|
|
],
|
|
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-019_en.pdf"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"cveMetadata": {
|
|
"assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
|
|
"assignerShortName": "Mitsubishi",
|
|
"cveId": "CVE-2021-20586",
|
|
"datePublished": "2021-01-29T14:54:32.000Z",
|
|
"dateReserved": "2020-12-17T00:00:00.000Z",
|
|
"dateUpdated": "2024-08-03T17:45:44.779Z",
|
|
"state": "PUBLISHED"
|
|
},
|
|
"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.1"
|
|
} |