"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"cveMetadata": {
"cveId": "CVE-2025-7746",
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"state": "PUBLISHED",
"assignerShortName": "schneider",
"dateReserved": "2025-07-17T09:10:51.541Z",
"datePublished": "2025-09-09T21:02:08.936Z",
"dateUpdated": "2025-11-03T18:14:06.463Z"
},
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ATV630/650/660/680/6A0/6B0/6L0 Altivar Process Drives",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ATV930/950/955/960/980/9A0/9B0/9L0/991/992/993 Altivar Process Drives",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ILC992 InterLink Converter",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ATV340E Altivar Machine Drives",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ATV6000 Medium Voltage Altivar Process Drives",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ATS490 Altivar Soft Starter",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VW3A3720 & VW3A3721 Altivar Process Communication Modules",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VW3A3530D: ATVdPAC module",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "v25.0",
"status": "affected",
"version": "all versions",
"versionType": "version"
}
]
}
],
"datePublic": "2025-09-09T04:01:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause an unvalidated data injected by a malicious user potentially leading to modify or read data in a victim’s browser."
}
],
"value": "CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause an unvalidated data injected by a malicious user potentially leading to modify or read data in a victim’s browser."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:N/SC:L/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider",
"dateUpdated": "2025-09-09T21:02:08.936Z"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-252-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2025-252-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
},
"adp": [
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2025-09-10T13:40:20.821038Z",
"id": "CVE-2025-7746",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2025-09-10T16:10:34.376Z"
}
},
{
"title": "CVE Program Container",
"references": [
{
"url": "http://seclists.org/fulldisclosure/2025/Sep/69"
}
],
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2025-11-03T18:14:06.463Z"
}
}
]
}
}