Files
vuln-cve/data/2025/7xxx/CVE-2025-7548.json
T

215 lines
8.3 KiB
JSON

{
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"cveMetadata": {
"cveId": "CVE-2025-7548",
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"state": "PUBLISHED",
"assignerShortName": "VulDB",
"dateReserved": "2025-07-12T17:06:22.580Z",
"datePublished": "2025-07-13T22:32:07.492Z",
"dateUpdated": "2025-07-14T15:56:48.926Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB",
"dateUpdated": "2025-07-13T22:32:07.492Z"
},
"title": "Tenda FH1201 SafeEmailFilter formSafeEmailFilter stack-based overflow",
"problemTypes": [
{
"descriptions": [
{
"type": "CWE",
"cweId": "CWE-121",
"lang": "en",
"description": "Stack-based Buffer Overflow"
}
]
},
{
"descriptions": [
{
"type": "CWE",
"cweId": "CWE-119",
"lang": "en",
"description": "Memory Corruption"
}
]
}
],
"affected": [
{
"vendor": "Tenda",
"product": "FH1201",
"versions": [
{
"version": "1.2.0.14(408)",
"status": "affected"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Tenda FH1201 1.2.0.14(408) and classified as critical. This vulnerability affects the function formSafeEmailFilter of the file /goform/SafeEmailFilter. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "In Tenda FH1201 1.2.0.14(408) wurde eine kritische Schwachstelle gefunden. Das betrifft die Funktion formSafeEmailFilter der Datei /goform/SafeEmailFilter. Durch das Manipulieren des Arguments page mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann über das Netzwerk angegangen werden. Der Exploit steht zur öffentlichen Verfügung."
}
],
"metrics": [
{
"cvssV4_0": {
"version": "4.0",
"baseScore": 8.7,
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"baseSeverity": "HIGH"
}
},
{
"cvssV3_1": {
"version": "3.1",
"baseScore": 8.8,
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"baseSeverity": "HIGH"
}
},
{
"cvssV3_0": {
"version": "3.0",
"baseScore": 8.8,
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"baseSeverity": "HIGH"
}
},
{
"cvssV2_0": {
"version": "2.0",
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR"
}
}
],
"timeline": [
{
"time": "2025-07-12T00:00:00.000Z",
"lang": "en",
"value": "Advisory disclosed"
},
{
"time": "2025-07-12T02:00:00.000Z",
"lang": "en",
"value": "VulDB entry created"
},
{
"time": "2025-07-12T19:11:32.000Z",
"lang": "en",
"value": "VulDB entry last update"
}
],
"credits": [
{
"lang": "en",
"value": "panda_0x1 (VulDB User)",
"type": "reporter"
}
],
"references": [
{
"url": "https://vuldb.com/?id.316246",
"name": "VDB-316246 | Tenda FH1201 SafeEmailFilter formSafeEmailFilter stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
]
},
{
"url": "https://vuldb.com/?ctiid.316246",
"name": "VDB-316246 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
]
},
{
"url": "https://vuldb.com/?submit.614658",
"name": "Submit #614658 | Tenda FH1201 V1.2.0.14(408) Buffer Overflow",
"tags": [
"third-party-advisory"
]
},
{
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1201/formSafeEmailFilter.md",
"tags": [
"related"
]
},
{
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1201/formSafeEmailFilter.md#poc",
"tags": [
"exploit"
]
},
{
"url": "https://www.tenda.com.cn/",
"tags": [
"product"
]
}
]
},
"adp": [
{
"references": [
{
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1201/formSafeEmailFilter.md#poc",
"tags": [
"exploit"
]
},
{
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1201/formSafeEmailFilter.md",
"tags": [
"exploit"
]
}
],
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2025-07-14T15:56:45.970390Z",
"id": "CVE-2025-7548",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2025-07-14T15:56:48.926Z"
}
}
]
}
}