Files
vuln-cve/data/2025/3xxx/CVE-2025-3237.json
T

194 lines
7.4 KiB
JSON

{
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"cveMetadata": {
"cveId": "CVE-2025-3237",
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"state": "PUBLISHED",
"assignerShortName": "VulDB",
"dateReserved": "2025-04-03T18:50:07.033Z",
"datePublished": "2025-04-04T10:00:15.289Z",
"dateUpdated": "2025-04-04T12:51:04.521Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB",
"dateUpdated": "2025-04-04T10:00:15.289Z"
},
"title": "Tenda FH1202 wrlwpsset access control",
"problemTypes": [
{
"descriptions": [
{
"type": "CWE",
"cweId": "CWE-284",
"lang": "en",
"description": "Improper Access Controls"
}
]
},
{
"descriptions": [
{
"type": "CWE",
"cweId": "CWE-266",
"lang": "en",
"description": "Incorrect Privilege Assignment"
}
]
}
],
"affected": [
{
"vendor": "Tenda",
"product": "FH1202",
"versions": [
{
"version": "1.2.0.14(408)",
"status": "affected"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been rated as critical. This issue affects some unknown processing of the file /goform/wrlwpsset. The manipulation leads to improper access controls. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Tenda FH1202 1.2.0.14(408) ausgemacht. Sie wurde als kritisch eingestuft. Betroffen davon ist ein unbekannter Prozess der Datei /goform/wrlwpsset. Durch Manipulation mit unbekannten Daten kann eine improper access controls-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei über das Netzwerk erfolgen. Der Exploit steht zur öffentlichen Verfügung."
}
],
"metrics": [
{
"cvssV4_0": {
"version": "4.0",
"baseScore": 6.9,
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
"baseSeverity": "MEDIUM"
}
},
{
"cvssV3_1": {
"version": "3.1",
"baseScore": 5.3,
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
"baseSeverity": "MEDIUM"
}
},
{
"cvssV3_0": {
"version": "3.0",
"baseScore": 5.3,
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
"baseSeverity": "MEDIUM"
}
},
{
"cvssV2_0": {
"version": "2.0",
"baseScore": 5,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N"
}
}
],
"timeline": [
{
"time": "2025-04-03T00:00:00.000Z",
"lang": "en",
"value": "Advisory disclosed"
},
{
"time": "2025-04-03T02:00:00.000Z",
"lang": "en",
"value": "VulDB entry created"
},
{
"time": "2025-04-03T20:55:13.000Z",
"lang": "en",
"value": "VulDB entry last update"
}
],
"credits": [
{
"lang": "en",
"value": "yhryhryhr_miemie (VulDB User)",
"type": "reporter"
}
],
"references": [
{
"url": "https://vuldb.com/?id.303263",
"name": "VDB-303263 | Tenda FH1202 wrlwpsset access control",
"tags": [
"vdb-entry"
]
},
{
"url": "https://vuldb.com/?ctiid.303263",
"name": "VDB-303263 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
]
},
{
"url": "https://vuldb.com/?submit.546368",
"name": "Submit #546368 | Tenda FH1202 V1.2.0.14(408) Improper Access Controls",
"tags": [
"third-party-advisory"
]
},
{
"url": "https://lavender-bicycle-a5a.notion.site/Tenda-FH1202-wrlwpsset-1bc53a41781f80aeb9a6de676fe25e6d?pvs=4",
"tags": [
"exploit"
]
},
{
"url": "https://www.tenda.com.cn/",
"tags": [
"product"
]
}
]
},
"adp": [
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2025-04-04T12:50:20.391141Z",
"id": "CVE-2025-3237",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2025-04-04T12:51:04.521Z"
}
}
]
}
}