"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.2",
|
|
"cveMetadata": {
|
|
"cveId": "CVE-2025-2884",
|
|
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
|
|
"state": "PUBLISHED",
|
|
"assignerShortName": "certcc",
|
|
"dateReserved": "2025-03-27T21:01:41.908Z",
|
|
"datePublished": "2025-06-10T17:29:19.463Z",
|
|
"dateUpdated": "2026-10-15T01:01:59.300Z"
|
|
},
|
|
"containers": {
|
|
"cna": {
|
|
"title": "Out-of-Bounds read vulnerability in TCG TPM2.0 reference implementation",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "TCG TPM2.0 Reference implementation's CryptHmacSign helper function is vulnerable to Out-of-Bounds read due to the lack of validation the signature scheme with the signature key's algorithm. See Errata Revision 1.83 and advisory TCGVRT0009 for TCG standard TPM2.0"
|
|
}
|
|
],
|
|
"source": {
|
|
"discovery": "INTERNAL"
|
|
},
|
|
"affected": [
|
|
{
|
|
"vendor": "Trusted Computing Group",
|
|
"product": "TPM2.0",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "1.83",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"description": "CWE-125 Out-of-bounds Read"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://trustedcomputinggroup.org/about/security/"
|
|
},
|
|
{
|
|
"url": "https://trustedcomputinggroup.org/wp-content/uploads/TPM2.0-Library-Spec-v1.83-Errata_v1_pub.pdf",
|
|
"name": "TPM2.0 Errata"
|
|
},
|
|
{
|
|
"url": "https://trustedcomputinggroup.org/wp-content/uploads/VRT0009-Advisory-FINAL.pdf",
|
|
"name": "Vendor Advisory"
|
|
},
|
|
{
|
|
"url": "https://github.com/stefanberger/libtpms/commit/04b2d8e9afc0a9b6bffe562a23e58c0de11532d1",
|
|
"name": "Vendor Patch"
|
|
},
|
|
{
|
|
"url": "https://www.cve.org/CVERecord?id=CVE-2025-49133",
|
|
"name": "Related CVE"
|
|
}
|
|
],
|
|
"x_generator": {
|
|
"engine": "VINCE 3.0.20",
|
|
"env": "prod",
|
|
"origin": "https://cveawg.mitre.org/api/cve/CVE-2025-2884"
|
|
},
|
|
"providerMetadata": {
|
|
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
|
|
"shortName": "certcc",
|
|
"dateUpdated": "2025-06-13T18:22:21.856Z"
|
|
},
|
|
"metrics": [
|
|
{
|
|
"other": {
|
|
"type": "ssvcV1_0_1",
|
|
"content": {
|
|
"id": "CVE-2025-2884",
|
|
"selections": [
|
|
{
|
|
"namespace": "ssvc",
|
|
"version": "1.0.0",
|
|
"values": [
|
|
"none"
|
|
],
|
|
"name": "Exploitation"
|
|
},
|
|
{
|
|
"namespace": "ssvc",
|
|
"version": "2.0.0",
|
|
"values": [
|
|
"no"
|
|
],
|
|
"name": "Automatable"
|
|
},
|
|
{
|
|
"namespace": "ssvc",
|
|
"version": "1.0.0",
|
|
"values": [
|
|
"partial"
|
|
],
|
|
"name": "Technical Impact"
|
|
},
|
|
{
|
|
"namespace": "ssvc",
|
|
"version": "1.0.0",
|
|
"values": [
|
|
"medium"
|
|
],
|
|
"name": "Mission & Well-being"
|
|
}
|
|
],
|
|
"timestamp": "2025-06-13T17:22:30.584Z"
|
|
}
|
|
}
|
|
}
|
|
]
|
|
},
|
|
"adp": [
|
|
{
|
|
"title": "CVE Program Container",
|
|
"references": [
|
|
{
|
|
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-01209.html"
|
|
},
|
|
{
|
|
"url": "https://www.kb.cert.org/vuls/id/282450"
|
|
}
|
|
],
|
|
"providerMetadata": {
|
|
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"shortName": "CVE",
|
|
"dateUpdated": "2025-06-10T19:02:29.811Z"
|
|
}
|
|
},
|
|
{
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"type": "CWE",
|
|
"cweId": "CWE-125",
|
|
"lang": "en",
|
|
"description": "CWE-125 Out-of-bounds Read"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"metrics": [
|
|
{
|
|
"cvssV3_1": {
|
|
"scope": "UNCHANGED",
|
|
"version": "3.1",
|
|
"baseScore": 6.6,
|
|
"attackVector": "LOCAL",
|
|
"baseSeverity": "MEDIUM",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:H",
|
|
"integrityImpact": "NONE",
|
|
"userInteraction": "REQUIRED",
|
|
"attackComplexity": "LOW",
|
|
"availabilityImpact": "HIGH",
|
|
"privilegesRequired": "LOW",
|
|
"confidentialityImpact": "HIGH"
|
|
}
|
|
},
|
|
{
|
|
"other": {
|
|
"type": "ssvc",
|
|
"content": {
|
|
"timestamp": "2025-06-13T01:41:10.489446Z",
|
|
"id": "CVE-2025-2884",
|
|
"options": [
|
|
{
|
|
"Exploitation": "none"
|
|
},
|
|
{
|
|
"Automatable": "no"
|
|
},
|
|
{
|
|
"Technical Impact": "partial"
|
|
}
|
|
],
|
|
"role": "CISA Coordinator",
|
|
"version": "2.0.3"
|
|
}
|
|
}
|
|
}
|
|
],
|
|
"title": "CISA ADP Vulnrichment",
|
|
"providerMetadata": {
|
|
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
|
"shortName": "CISA-ADP",
|
|
"dateUpdated": "2025-06-13T01:46:13.802Z"
|
|
}
|
|
},
|
|
{
|
|
"x_adpType": "supplier",
|
|
"providerMetadata": {
|
|
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
|
|
"shortName": "siemens-SADP",
|
|
"dateUpdated": "2026-10-15T01:01:59.300Z"
|
|
},
|
|
"affected": [
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC CN 4100",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC Field PG M5",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC Field PG M6",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V26.01.14",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC IPC BX-32A",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V29.01.09",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC IPC BX-39A",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V29.01.09",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC IPC BX-56A",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V32.01.09",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC IPC BX-59A",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V32.01.09",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC IPC MD-57A",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V30.01.10",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC IPC PX-32A",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V29.01.09",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC IPC PX-39A",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V29.01.09",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC IPC PX-39A PRO",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V29.01.09",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC IPC RW-528A",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V34.01.02",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC IPC RW-548A",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V34.01.02",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC IPC227E",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC IPC277E",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC IPC427E",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V21.01.20",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC IPC477E",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V21.01.20",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC IPC477E PRO",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V21.01.20",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC IPC627E",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V25.02.16",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC IPC647E",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V25.02.16",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC IPC677E",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V25.02.16",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC IPC847E",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V25.02.16",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC ITP1000",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS IPC427E",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V21.01.20",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/html/ssa-628843.html"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
} |