Files
vuln-cve/data/2025/2xxx/CVE-2025-2230.json
T

189 lines
8.7 KiB
JSON
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
{
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"cveMetadata": {
"cveId": "CVE-2025-2230",
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"state": "PUBLISHED",
"assignerShortName": "icscert",
"dateReserved": "2025-03-11T20:14:50.017Z",
"datePublished": "2025-03-13T18:14:43.573Z",
"dateUpdated": "2025-03-17T20:05:56.939Z"
},
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Intellispace Cardiovascular (ISCV)",
"vendor": "Philips",
"versions": [
{
"lessThanOrEqual": "5.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Joe Dillon reported these vulnerabilities to Philips."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A flaw exists in the Windows login flow where an AuthContext token can \nbe exploited for replay attacks and authentication bypass."
}
],
"value": "A flaw exists in the Windows login flow where an AuthContext token can \nbe exploited for replay attacks and authentication bypass."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287 Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert",
"dateUpdated": "2025-03-17T20:05:56.939Z"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-072-01"
},
{
"url": "https://www.philips.com/a-w/security/security-advisories.html"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "<p>Philips recommends the following mitigations:</p>\n<ul>\n<li>\n\n<span style=\"background-color: rgb(255, 255, 255);\">Resolved in ISCV 5.2, which was released in September 2020.</span>\n\n</li>\n\n<li>Philips recommends users upgrade ISCV installed base to the latest \nISCV version (at the time of this publication is 830089 – IntelliSpace \nCardiovacular 8.0.0.0)</li>\n<li>Please contact a local Philips sales (service) representative to learn how to engage this upgrade process.</li>\n<li>For managed services users, new releases will be made available upon\n resource availability. Releases are subject to country-specific \nregulations.</li>\n</ul>\n<p>Refer to the <a target=\"_blank\" rel=\"nofollow\" href=\"https://www.philips.com/a-w/security/security-advisories.html\">Philips advisory</a>for more details.\n\n<br></p>"
}
],
"value": "Philips recommends the following mitigations:\n\n\n\n * \n\nResolved in ISCV 5.2, which was released in September 2020.\n\n\n\n\n * Philips recommends users upgrade ISCV installed base to the latest \nISCV version (at the time of this publication is 830089 – IntelliSpace \nCardiovacular 8.0.0.0)\n\n * Please contact a local Philips sales (service) representative to learn how to engage this upgrade process.\n\n * For managed services users, new releases will be made available upon\n resource availability. Releases are subject to country-specific \nregulations.\n\n\n\n\nRefer to the Philips advisory https://www.philips.com/a-w/security/security-advisories.html for more details."
}
],
"source": {
"advisory": "ICSMA-25-072-01",
"discovery": "EXTERNAL"
},
"title": "Philips Intellispace Cardiovascular (ISCV) Improper Authentication",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
},
"adp": [
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2025-03-13T19:33:45.514056Z",
"id": "CVE-2025-2230",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2025-03-13T19:34:02.967Z"
}
}
]
}
}