"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"cveMetadata": {
"cveId": "CVE-2024-7986",
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"state": "PUBLISHED",
"assignerShortName": "Rockwell",
"dateReserved": "2024-08-19T20:06:24.873Z",
"datePublished": "2024-08-23T11:51:55.080Z",
"dateUpdated": "2024-08-28T16:21:02.832Z"
},
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ThinManager® ThinServer™",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "11.1.0-11.1.7 11.2.0-11.2.8 12.0.0-12.0.6 12.1.0-12.1.7 13.0.0-13.0.4 13.1.0-13.1.2 13.2.0-13.2.1"
}
]
}
],
"datePublic": "2024-08-22T13:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "<span style=\"background-color: rgb(255, 255, 255);\">A vulnerability exists in the Rockwell Automation&nbsp;</span>ThinManager® ThinServer&nbsp;<span style=\"background-color: rgb(255, 255, 255);\">that allows a threat actor to disclose sensitive information. A threat actor can exploit this vulnerability by abusing the ThinServer™ service to read arbitrary files by creating a junction that points to the target directory.</span>"
}
],
"value": "A vulnerability exists in the Rockwell Automation ThinManager® ThinServer that allows a threat actor to disclose sensitive information. A threat actor can exploit this vulnerability by abusing the ThinServer™ service to read arbitrary files by creating a junction that points to the target directory."
}
],
"impacts": [
{
"capecId": "CAPEC-576",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-576 Group Permission Footprinting"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell",
"dateUpdated": "2024-08-23T11:51:55.080Z"
},
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1692.html"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "<table><tbody><tr><td><p>Affected Product</p></td><td><p>First Known in software version</p></td><td><p>Corrected in software version</p></td></tr><tr><td><p>ThinManager® ThinServer™</p></td><td><p>11.1.0-11.1.7<br>11.2.0-11.2.8<br>12.0.0-12.0.6<br>12.1.0-12.1.7<br>13.0.0-13.0.4<br>13.1.0-13.1.2<br>13.2.0-13.2.1</p></td><td><p>11.1.8</p><p>11.2.9</p><p>12.0.7</p><p>12.1.8</p><p>13.0.5</p><p>13.1.3</p><p>13.2.2</p></td></tr></tbody></table><br><p><b>Mitigations and Workarounds</b></p><p>Customers using the affected software are encouraged to implement our suggested security best practices to minimize the risk of vulnerability.</p><p>· &nbsp; &nbsp; &nbsp; <a target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\">Security Best Practices</a></p>"
}
],
"value": "Affected Product\n\nFirst Known in software version\n\nCorrected in software version\n\nThinManager® ThinServer™\n\n11.1.0-11.1.7\n11.2.0-11.2.8\n12.0.0-12.0.6\n12.1.0-12.1.7\n13.0.0-13.0.4\n13.1.0-13.1.2\n13.2.0-13.2.1\n\n11.1.8\n\n11.2.9\n\n12.0.7\n\n12.1.8\n\n13.0.5\n\n13.1.3\n\n13.2.2\n\n\nMitigations and Workarounds\n\nCustomers using the affected software are encouraged to implement our suggested security best practices to minimize the risk of vulnerability.\n\n·       Security Best Practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight"
}
],
"source": {
"advisory": "SD1692",
"discovery": "EXTERNAL"
},
"title": "Rockwell Automation ThinManager® ThinServer™ Information Disclosure",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
},
"adp": [
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2024-08-28T16:20:54.169556Z",
"id": "CVE-2024-7986",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2024-08-28T16:21:02.832Z"
}
}
]
}
}