"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"cveMetadata": {
"cveId": "CVE-2024-7614",
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"state": "PUBLISHED",
"assignerShortName": "VulDB",
"dateReserved": "2024-08-08T14:28:35.326Z",
"datePublished": "2024-08-08T22:31:03.812Z",
"dateUpdated": "2024-08-15T17:19:10.011Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB",
"dateUpdated": "2024-08-08T22:31:03.812Z"
},
"title": "Tenda FH1206 qossetting fromqossetting stack-based overflow",
"problemTypes": [
{
"descriptions": [
{
"type": "CWE",
"cweId": "CWE-121",
"lang": "en",
"description": "CWE-121 Stack-based Buffer Overflow"
}
]
}
],
"affected": [
{
"vendor": "Tenda",
"product": "FH1206",
"versions": [
{
"version": "1.2.0.8(8155)",
"status": "affected"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda FH1206 1.2.0.8(8155). It has been classified as critical. Affected is the function fromqossetting of the file /goform/qossetting. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in Tenda FH1206 1.2.0.8(8155) ausgemacht. Betroffen hiervon ist die Funktion fromqossetting der Datei /goform/qossetting. Durch das Manipulieren des Arguments page mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff über das Netzwerk. Der Exploit steht zur öffentlichen Verfügung."
}
],
"metrics": [
{
"cvssV4_0": {
"version": "4.0",
"baseScore": 8.7,
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"baseSeverity": "HIGH"
}
},
{
"cvssV3_1": {
"version": "3.1",
"baseScore": 8.8,
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"baseSeverity": "HIGH"
}
},
{
"cvssV3_0": {
"version": "3.0",
"baseScore": 8.8,
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"baseSeverity": "HIGH"
}
},
{
"cvssV2_0": {
"version": "2.0",
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C"
}
}
],
"timeline": [
{
"time": "2024-08-08T00:00:00.000Z",
"lang": "en",
"value": "Advisory disclosed"
},
{
"time": "2024-08-08T02:00:00.000Z",
"lang": "en",
"value": "VulDB entry created"
},
{
"time": "2024-08-08T16:33:44.000Z",
"lang": "en",
"value": "VulDB entry last update"
}
],
"credits": [
{
"lang": "en",
"value": "BeaCox (VulDB User)",
"type": "reporter"
}
],
"references": [
{
"url": "https://vuldb.com/?id.273984",
"name": "VDB-273984 | Tenda FH1206 qossetting fromqossetting stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
]
},
{
"url": "https://vuldb.com/?ctiid.273984",
"name": "VDB-273984 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
]
},
{
"url": "https://vuldb.com/?submit.383692",
"name": "Submit #383692 | Tenda FH1206 1.2.0.8 Buffer Overflow",
"tags": [
"third-party-advisory"
]
},
{
"url": "https://github.com/BeaCox/IoT_vuln/tree/main/tenda/FH1206/qossetting_bof",
"tags": [
"exploit"
]
}
]
},
"adp": [
{
"affected": [
{
"vendor": "tenda",
"product": "fh1206_firmware",
"cpes": [
"cpe:2.3:o:tenda:fh1206_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"versions": [
{
"version": "1.2.0.8(8155)",
"status": "affected"
}
]
}
],
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2024-08-09T17:25:15.765728Z",
"id": "CVE-2024-7614",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2024-08-15T17:19:10.011Z"
}
}
]
}
}