"dataType": "CVE_RECORD",
|
||
"dataVersion": "5.1",
|
||
"cveMetadata": {
|
||
"cveId": "CVE-2024-4192",
|
||
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
|
||
"state": "PUBLISHED",
|
||
"assignerShortName": "icscert",
|
||
"dateReserved": "2024-04-25T14:55:16.868Z",
|
||
"datePublished": "2024-04-30T23:01:58.874Z",
|
||
"dateUpdated": "2024-09-03T18:16:25.046Z"
|
||
},
|
||
"containers": {
|
||
"cna": {
|
||
"affected": [
|
||
{
|
||
"defaultStatus": "unaffected",
|
||
"product": "CNCSoft-G2 DOPSoft",
|
||
"vendor": "Delta Electronics",
|
||
"versions": [
|
||
{
|
||
"lessThanOrEqual": "Versions 2.0.0.5 (with DOPSoft v5.0.0.93)",
|
||
"status": "affected",
|
||
"version": " 0",
|
||
"versionType": "custom"
|
||
}
|
||
]
|
||
}
|
||
],
|
||
"credits": [
|
||
{
|
||
"lang": "en",
|
||
"type": "finder",
|
||
"value": "Natnael Samson working with Trend Micro Zero Day Initiative reported this vulnerability to CISA."
|
||
}
|
||
],
|
||
"descriptions": [
|
||
{
|
||
"lang": "en",
|
||
"supportingMedia": [
|
||
{
|
||
"base64": false,
|
||
"type": "text/html",
|
||
"value": "\n\n<span style=\"background-color: rgb(241, 241, 242);\">Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process.</span>\n\n"
|
||
}
|
||
],
|
||
"value": "\nDelta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process.\n\n"
|
||
}
|
||
],
|
||
"metrics": [
|
||
{
|
||
"cvssV3_1": {
|
||
"attackComplexity": "LOW",
|
||
"attackVector": "LOCAL",
|
||
"availabilityImpact": "HIGH",
|
||
"baseScore": 7.8,
|
||
"baseSeverity": "HIGH",
|
||
"confidentialityImpact": "HIGH",
|
||
"integrityImpact": "HIGH",
|
||
"privilegesRequired": "NONE",
|
||
"scope": "UNCHANGED",
|
||
"userInteraction": "REQUIRED",
|
||
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
|
||
"version": "3.1"
|
||
},
|
||
"format": "CVSS",
|
||
"scenarios": [
|
||
{
|
||
"lang": "en",
|
||
"value": "GENERAL"
|
||
}
|
||
]
|
||
}
|
||
],
|
||
"problemTypes": [
|
||
{
|
||
"descriptions": [
|
||
{
|
||
"cweId": "CWE-121",
|
||
"description": "CWE-121 Stack-based Buffer Overflow",
|
||
"lang": "en",
|
||
"type": "CWE"
|
||
}
|
||
]
|
||
}
|
||
],
|
||
"providerMetadata": {
|
||
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
|
||
"shortName": "icscert",
|
||
"dateUpdated": "2024-04-30T23:01:58.874Z"
|
||
},
|
||
"references": [
|
||
{
|
||
"tags": [
|
||
"government-resource"
|
||
],
|
||
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-121-01"
|
||
}
|
||
],
|
||
"solutions": [
|
||
{
|
||
"lang": "en",
|
||
"supportingMedia": [
|
||
{
|
||
"base64": false,
|
||
"type": "text/html",
|
||
"value": "\n\n<span style=\"background-color: rgb(255, 255, 255);\">Delta Electronics recommends users update to </span><a target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1&q=CNCSoft&sort_expr=cdate&sort_dir=DESC\">CNCSoft-G2 v2.1.0.4</a><span style=\"background-color: rgb(255, 255, 255);\"> or later.</span>\n\n<br>"
|
||
}
|
||
],
|
||
"value": "\nDelta Electronics recommends users update to CNCSoft-G2 v2.1.0.4 https://downloadcenter.deltaww.com/en-US/DownloadCenter or later.\n\n"
|
||
}
|
||
],
|
||
"source": {
|
||
"discovery": "UNKNOWN"
|
||
},
|
||
"title": "Stack-based Buffer Overflow vulnerability in Delta Electronics CNCSoft-G2 DOPSoft",
|
||
"x_generator": {
|
||
"engine": "Vulnogram 0.1.0-dev"
|
||
}
|
||
},
|
||
"adp": [
|
||
{
|
||
"providerMetadata": {
|
||
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
|
||
"shortName": "CVE",
|
||
"dateUpdated": "2024-08-01T20:33:52.537Z"
|
||
},
|
||
"title": "CVE Program Container",
|
||
"references": [
|
||
{
|
||
"tags": [
|
||
"government-resource",
|
||
"x_transferred"
|
||
],
|
||
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-121-01"
|
||
}
|
||
]
|
||
},
|
||
{
|
||
"affected": [
|
||
{
|
||
"vendor": "delta_electronics",
|
||
"product": "cncsoft-g2",
|
||
"cpes": [
|
||
"cpe:2.3:a:delta_electronics:cncsoft-g2:*:*:*:*:*:*:*:*"
|
||
],
|
||
"defaultStatus": "unknown",
|
||
"versions": [
|
||
{
|
||
"version": "0",
|
||
"status": "affected",
|
||
"lessThanOrEqual": "2.0.0.5",
|
||
"versionType": "custom"
|
||
}
|
||
]
|
||
}
|
||
],
|
||
"metrics": [
|
||
{
|
||
"other": {
|
||
"type": "ssvc",
|
||
"content": {
|
||
"timestamp": "2024-08-07T13:35:46.576164Z",
|
||
"id": "CVE-2024-4192",
|
||
"options": [
|
||
{
|
||
"Exploitation": "none"
|
||
},
|
||
{
|
||
"Automatable": "no"
|
||
},
|
||
{
|
||
"Technical Impact": "total"
|
||
}
|
||
],
|
||
"role": "CISA Coordinator",
|
||
"version": "2.0.3"
|
||
}
|
||
}
|
||
}
|
||
],
|
||
"title": "CISA ADP Vulnrichment",
|
||
"providerMetadata": {
|
||
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
||
"shortName": "CISA-ADP",
|
||
"dateUpdated": "2024-09-03T18:16:25.046Z"
|
||
}
|
||
}
|
||
]
|
||
}
|
||
} |