230 lines
8.9 KiB
JSON
230 lines
8.9 KiB
JSON
{
|
|
"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.1",
|
|
"cveMetadata": {
|
|
"cveId": "CVE-2024-4121",
|
|
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
|
|
"state": "PUBLISHED",
|
|
"assignerShortName": "VulDB",
|
|
"dateReserved": "2024-04-24T08:19:14.033Z",
|
|
"datePublished": "2024-04-24T18:00:06.618Z",
|
|
"dateUpdated": "2024-08-01T20:33:52.570Z"
|
|
},
|
|
"containers": {
|
|
"cna": {
|
|
"providerMetadata": {
|
|
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
|
|
"shortName": "VulDB",
|
|
"dateUpdated": "2024-04-24T18:00:06.618Z"
|
|
},
|
|
"title": "Tenda W15E formQOSRuleDel stack-based overflow",
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"type": "CWE",
|
|
"cweId": "CWE-121",
|
|
"lang": "en",
|
|
"description": "CWE-121 Stack-based Buffer Overflow"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"affected": [
|
|
{
|
|
"vendor": "Tenda",
|
|
"product": "W15E",
|
|
"versions": [
|
|
{
|
|
"version": "15.11.0.14",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A vulnerability classified as critical has been found in Tenda W15E 15.11.0.14. Affected is the function formQOSRuleDel. The manipulation of the argument qosIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The identifier of this vulnerability is VDB-261864. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
|
|
},
|
|
{
|
|
"lang": "de",
|
|
"value": "Es wurde eine kritische Schwachstelle in Tenda W15E 15.11.0.14 entdeckt. Betroffen hiervon ist die Funktion formQOSRuleDel. Durch das Beeinflussen des Arguments qosIndex mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff über das Netzwerk."
|
|
}
|
|
],
|
|
"metrics": [
|
|
{
|
|
"cvssV3_1": {
|
|
"version": "3.1",
|
|
"baseScore": 8.8,
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
|
|
"baseSeverity": "HIGH"
|
|
}
|
|
},
|
|
{
|
|
"cvssV3_0": {
|
|
"version": "3.0",
|
|
"baseScore": 8.8,
|
|
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
|
|
"baseSeverity": "HIGH"
|
|
}
|
|
},
|
|
{
|
|
"cvssV2_0": {
|
|
"version": "2.0",
|
|
"baseScore": 9,
|
|
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C"
|
|
}
|
|
}
|
|
],
|
|
"timeline": [
|
|
{
|
|
"time": "2024-04-24T00:00:00.000Z",
|
|
"lang": "en",
|
|
"value": "Advisory disclosed"
|
|
},
|
|
{
|
|
"time": "2024-04-24T02:00:00.000Z",
|
|
"lang": "en",
|
|
"value": "VulDB entry created"
|
|
},
|
|
{
|
|
"time": "2024-04-24T10:24:53.000Z",
|
|
"lang": "en",
|
|
"value": "VulDB entry last update"
|
|
}
|
|
],
|
|
"credits": [
|
|
{
|
|
"lang": "en",
|
|
"value": "wxhwxhwxh_mie (VulDB User)",
|
|
"type": "reporter"
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://vuldb.com/?id.261864",
|
|
"name": "VDB-261864 | Tenda W15E formQOSRuleDel stack-based overflow",
|
|
"tags": [
|
|
"vdb-entry",
|
|
"technical-description"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://vuldb.com/?ctiid.261864",
|
|
"name": "VDB-261864 | CTI Indicators (IOB, IOC, IOA)",
|
|
"tags": [
|
|
"signature",
|
|
"permissions-required"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://vuldb.com/?submit.317826",
|
|
"name": "Submit #317826 | Tenda W15EV1.0 V15.11.0.14 Buffer Overflow",
|
|
"tags": [
|
|
"third-party-advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formQOSRuleDel.md",
|
|
"tags": [
|
|
"related"
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"adp": [
|
|
{
|
|
"title": "CISA ADP Vulnrichment",
|
|
"metrics": [
|
|
{
|
|
"other": {
|
|
"type": "ssvc",
|
|
"content": {
|
|
"id": "CVE-2024-4121",
|
|
"role": "CISA Coordinator",
|
|
"options": [
|
|
{
|
|
"Exploitation": "none"
|
|
},
|
|
{
|
|
"Automatable": "no"
|
|
},
|
|
{
|
|
"Technical Impact": "partial"
|
|
}
|
|
],
|
|
"version": "2.0.3",
|
|
"timestamp": "2024-04-30T15:08:58.999891Z"
|
|
}
|
|
}
|
|
}
|
|
],
|
|
"affected": [
|
|
{
|
|
"cpes": [
|
|
"cpe:2.3:o:tenda:w15e_firmware:15.11.0.14:*:*:*:*:*:*:*"
|
|
],
|
|
"vendor": "tenda",
|
|
"product": "w15e_firmware",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "15.11.0.14"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
}
|
|
],
|
|
"providerMetadata": {
|
|
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
|
"shortName": "CISA-ADP",
|
|
"dateUpdated": "2024-06-04T17:54:46.614Z"
|
|
}
|
|
},
|
|
{
|
|
"providerMetadata": {
|
|
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"shortName": "CVE",
|
|
"dateUpdated": "2024-08-01T20:33:52.570Z"
|
|
},
|
|
"title": "CVE Program Container",
|
|
"references": [
|
|
{
|
|
"url": "https://vuldb.com/?id.261864",
|
|
"name": "VDB-261864 | Tenda W15E formQOSRuleDel stack-based overflow",
|
|
"tags": [
|
|
"vdb-entry",
|
|
"technical-description",
|
|
"x_transferred"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://vuldb.com/?ctiid.261864",
|
|
"name": "VDB-261864 | CTI Indicators (IOB, IOC, IOA)",
|
|
"tags": [
|
|
"signature",
|
|
"permissions-required",
|
|
"x_transferred"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://vuldb.com/?submit.317826",
|
|
"name": "Submit #317826 | Tenda W15EV1.0 V15.11.0.14 Buffer Overflow",
|
|
"tags": [
|
|
"third-party-advisory",
|
|
"x_transferred"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formQOSRuleDel.md",
|
|
"tags": [
|
|
"related",
|
|
"x_transferred"
|
|
]
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
} |