230 lines
9.1 KiB
JSON
230 lines
9.1 KiB
JSON
{
|
|
"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.1",
|
|
"cveMetadata": {
|
|
"cveId": "CVE-2024-4113",
|
|
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
|
|
"state": "PUBLISHED",
|
|
"assignerShortName": "VulDB",
|
|
"dateReserved": "2024-04-24T08:18:51.119Z",
|
|
"datePublished": "2024-04-24T15:00:06.772Z",
|
|
"dateUpdated": "2024-08-01T20:33:52.536Z"
|
|
},
|
|
"containers": {
|
|
"cna": {
|
|
"providerMetadata": {
|
|
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
|
|
"shortName": "VulDB",
|
|
"dateUpdated": "2024-04-24T15:00:06.772Z"
|
|
},
|
|
"title": "Tenda TX9 SetSysTimeCfg sub_42D4DC stack-based overflow",
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"type": "CWE",
|
|
"cweId": "CWE-121",
|
|
"lang": "en",
|
|
"description": "CWE-121 Stack-based Buffer Overflow"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"affected": [
|
|
{
|
|
"vendor": "Tenda",
|
|
"product": "TX9",
|
|
"versions": [
|
|
{
|
|
"version": "22.03.02.10",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A vulnerability classified as critical was found in Tenda TX9 22.03.02.10. This vulnerability affects the function sub_42D4DC of the file /goform/SetSysTimeCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261856. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
|
|
},
|
|
{
|
|
"lang": "de",
|
|
"value": "In Tenda TX9 22.03.02.10 wurde eine Schwachstelle entdeckt. Sie wurde als kritisch eingestuft. Das betrifft die Funktion sub_42D4DC der Datei /goform/SetSysTimeCfg. Dank Manipulation des Arguments time mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann über das Netzwerk angegangen werden. Der Exploit steht zur öffentlichen Verfügung."
|
|
}
|
|
],
|
|
"metrics": [
|
|
{
|
|
"cvssV3_1": {
|
|
"version": "3.1",
|
|
"baseScore": 8.8,
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
|
|
"baseSeverity": "HIGH"
|
|
}
|
|
},
|
|
{
|
|
"cvssV3_0": {
|
|
"version": "3.0",
|
|
"baseScore": 8.8,
|
|
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
|
|
"baseSeverity": "HIGH"
|
|
}
|
|
},
|
|
{
|
|
"cvssV2_0": {
|
|
"version": "2.0",
|
|
"baseScore": 9,
|
|
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C"
|
|
}
|
|
}
|
|
],
|
|
"timeline": [
|
|
{
|
|
"time": "2024-04-24T00:00:00.000Z",
|
|
"lang": "en",
|
|
"value": "Advisory disclosed"
|
|
},
|
|
{
|
|
"time": "2024-04-24T02:00:00.000Z",
|
|
"lang": "en",
|
|
"value": "VulDB entry created"
|
|
},
|
|
{
|
|
"time": "2024-04-24T10:24:41.000Z",
|
|
"lang": "en",
|
|
"value": "VulDB entry last update"
|
|
}
|
|
],
|
|
"credits": [
|
|
{
|
|
"lang": "en",
|
|
"value": "wxhwxhwxh_tutu (VulDB User)",
|
|
"type": "reporter"
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://vuldb.com/?id.261856",
|
|
"name": "VDB-261856 | Tenda TX9 SetSysTimeCfg sub_42D4DC stack-based overflow",
|
|
"tags": [
|
|
"vdb-entry",
|
|
"technical-description"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://vuldb.com/?ctiid.261856",
|
|
"name": "VDB-261856 | CTI Indicators (IOB, IOC, IOA)",
|
|
"tags": [
|
|
"signature",
|
|
"permissions-required"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://vuldb.com/?submit.317217",
|
|
"name": "Submit #317217 | Tenda TX9 Pro V22.03.02.10 buffer overflow",
|
|
"tags": [
|
|
"third-party-advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/TX9/fromSetSysTime.md",
|
|
"tags": [
|
|
"exploit"
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"adp": [
|
|
{
|
|
"affected": [
|
|
{
|
|
"vendor": "tenda",
|
|
"product": "tx9_pro_firmware",
|
|
"cpes": [
|
|
"cpe:2.3:o:tenda:tx9_pro_firmware:22.03.02.10:*:*:*:*:*:*:*"
|
|
],
|
|
"defaultStatus": "unknown",
|
|
"versions": [
|
|
{
|
|
"version": "22.03.02.10",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"metrics": [
|
|
{
|
|
"other": {
|
|
"type": "ssvc",
|
|
"content": {
|
|
"timestamp": "2024-07-03T17:15:47.958452Z",
|
|
"id": "CVE-2024-4113",
|
|
"options": [
|
|
{
|
|
"Exploitation": "poc"
|
|
},
|
|
{
|
|
"Automatable": "no"
|
|
},
|
|
{
|
|
"Technical Impact": "total"
|
|
}
|
|
],
|
|
"role": "CISA Coordinator",
|
|
"version": "2.0.3"
|
|
}
|
|
}
|
|
}
|
|
],
|
|
"title": "CISA ADP Vulnrichment",
|
|
"providerMetadata": {
|
|
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
|
"shortName": "CISA-ADP",
|
|
"dateUpdated": "2024-07-03T21:02:35.914Z"
|
|
}
|
|
},
|
|
{
|
|
"providerMetadata": {
|
|
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"shortName": "CVE",
|
|
"dateUpdated": "2024-08-01T20:33:52.536Z"
|
|
},
|
|
"title": "CVE Program Container",
|
|
"references": [
|
|
{
|
|
"url": "https://vuldb.com/?id.261856",
|
|
"name": "VDB-261856 | Tenda TX9 SetSysTimeCfg sub_42D4DC stack-based overflow",
|
|
"tags": [
|
|
"vdb-entry",
|
|
"technical-description",
|
|
"x_transferred"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://vuldb.com/?ctiid.261856",
|
|
"name": "VDB-261856 | CTI Indicators (IOB, IOC, IOA)",
|
|
"tags": [
|
|
"signature",
|
|
"permissions-required",
|
|
"x_transferred"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://vuldb.com/?submit.317217",
|
|
"name": "Submit #317217 | Tenda TX9 Pro V22.03.02.10 buffer overflow",
|
|
"tags": [
|
|
"third-party-advisory",
|
|
"x_transferred"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/TX9/fromSetSysTime.md",
|
|
"tags": [
|
|
"exploit",
|
|
"x_transferred"
|
|
]
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
} |