Files
vuln-cve/data/2024/4xxx/CVE-2024-4111.json
T

214 lines
8.5 KiB
JSON

{
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"cveMetadata": {
"cveId": "CVE-2024-4111",
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"state": "PUBLISHED",
"assignerShortName": "VulDB",
"dateReserved": "2024-04-24T08:18:46.209Z",
"datePublished": "2024-04-24T14:00:05.565Z",
"dateUpdated": "2024-08-01T20:33:52.366Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB",
"dateUpdated": "2024-04-24T14:00:05.565Z"
},
"title": "Tenda TX9 SetLEDCfg sub_42BD7C stack-based overflow",
"problemTypes": [
{
"descriptions": [
{
"type": "CWE",
"cweId": "CWE-121",
"lang": "en",
"description": "CWE-121 Stack-based Buffer Overflow"
}
]
}
],
"affected": [
{
"vendor": "Tenda",
"product": "TX9",
"versions": [
{
"version": "22.03.02.10",
"status": "affected"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda TX9 22.03.02.10. It has been rated as critical. Affected by this issue is the function sub_42BD7C of the file /goform/SetLEDCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261854 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in Tenda TX9 22.03.02.10 ausgemacht. Hierbei geht es um die Funktion sub_42BD7C der Datei /goform/SetLEDCfg. Durch Beeinflussen des Arguments time mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff über das Netzwerk. Der Exploit steht zur öffentlichen Verfügung."
}
],
"metrics": [
{
"cvssV3_1": {
"version": "3.1",
"baseScore": 8.8,
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"baseSeverity": "HIGH"
}
},
{
"cvssV3_0": {
"version": "3.0",
"baseScore": 8.8,
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"baseSeverity": "HIGH"
}
},
{
"cvssV2_0": {
"version": "2.0",
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C"
}
}
],
"timeline": [
{
"time": "2024-04-24T00:00:00.000Z",
"lang": "en",
"value": "Advisory disclosed"
},
{
"time": "2024-04-24T02:00:00.000Z",
"lang": "en",
"value": "VulDB entry created"
},
{
"time": "2024-04-24T10:24:37.000Z",
"lang": "en",
"value": "VulDB entry last update"
}
],
"credits": [
{
"lang": "en",
"value": "yhryhryhr_tu (VulDB User)",
"type": "reporter"
}
],
"references": [
{
"url": "https://vuldb.com/?id.261854",
"name": "VDB-261854 | Tenda TX9 SetLEDCfg sub_42BD7C stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
]
},
{
"url": "https://vuldb.com/?ctiid.261854",
"name": "VDB-261854 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
]
},
{
"url": "https://vuldb.com/?submit.317205",
"name": "Submit #317205 | Tenda TX9 Pro V22.03.02.10 buffer overflow",
"tags": [
"third-party-advisory"
]
},
{
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/TX9/SetLEDCfg.md",
"tags": [
"exploit"
]
}
]
},
"adp": [
{
"title": "CISA ADP Vulnrichment",
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"id": "CVE-2024-4111",
"role": "CISA Coordinator",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2024-04-29T18:30:42.968664Z"
}
}
}
],
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2024-06-04T17:53:46.885Z"
}
},
{
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2024-08-01T20:33:52.366Z"
},
"title": "CVE Program Container",
"references": [
{
"url": "https://vuldb.com/?id.261854",
"name": "VDB-261854 | Tenda TX9 SetLEDCfg sub_42BD7C stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
]
},
{
"url": "https://vuldb.com/?ctiid.261854",
"name": "VDB-261854 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
]
},
{
"url": "https://vuldb.com/?submit.317205",
"name": "Submit #317205 | Tenda TX9 Pro V22.03.02.10 buffer overflow",
"tags": [
"third-party-advisory",
"x_transferred"
]
},
{
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/TX9/SetLEDCfg.md",
"tags": [
"exploit",
"x_transferred"
]
}
]
}
]
}
}