230 lines
9.2 KiB
JSON
230 lines
9.2 KiB
JSON
{
|
|
"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.1",
|
|
"cveMetadata": {
|
|
"cveId": "CVE-2024-3909",
|
|
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
|
|
"state": "PUBLISHED",
|
|
"assignerShortName": "VulDB",
|
|
"dateReserved": "2024-04-17T05:42:53.219Z",
|
|
"datePublished": "2024-04-17T11:31:05.865Z",
|
|
"dateUpdated": "2024-08-01T20:26:57.136Z"
|
|
},
|
|
"containers": {
|
|
"cna": {
|
|
"providerMetadata": {
|
|
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
|
|
"shortName": "VulDB",
|
|
"dateUpdated": "2024-04-17T11:31:05.865Z"
|
|
},
|
|
"title": "Tenda AC500 execCommand formexeCommand stack-based overflow",
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"type": "CWE",
|
|
"cweId": "CWE-121",
|
|
"lang": "en",
|
|
"description": "CWE-121 Stack-based Buffer Overflow"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"affected": [
|
|
{
|
|
"vendor": "Tenda",
|
|
"product": "AC500",
|
|
"versions": [
|
|
{
|
|
"version": "2.0.1.9(1307)",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A vulnerability classified as critical was found in Tenda AC500 2.0.1.9(1307). Affected by this vulnerability is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
|
|
},
|
|
{
|
|
"lang": "de",
|
|
"value": "In Tenda AC500 2.0.1.9(1307) wurde eine kritische Schwachstelle entdeckt. Es geht um die Funktion formexeCommand der Datei /goform/execCommand. Mittels dem Manipulieren des Arguments cmdinput mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann über das Netzwerk erfolgen. Der Exploit steht zur öffentlichen Verfügung."
|
|
}
|
|
],
|
|
"metrics": [
|
|
{
|
|
"cvssV3_1": {
|
|
"version": "3.1",
|
|
"baseScore": 8.8,
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
|
|
"baseSeverity": "HIGH"
|
|
}
|
|
},
|
|
{
|
|
"cvssV3_0": {
|
|
"version": "3.0",
|
|
"baseScore": 8.8,
|
|
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
|
|
"baseSeverity": "HIGH"
|
|
}
|
|
},
|
|
{
|
|
"cvssV2_0": {
|
|
"version": "2.0",
|
|
"baseScore": 9,
|
|
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C"
|
|
}
|
|
}
|
|
],
|
|
"timeline": [
|
|
{
|
|
"time": "2024-04-17T00:00:00.000Z",
|
|
"lang": "en",
|
|
"value": "Advisory disclosed"
|
|
},
|
|
{
|
|
"time": "2024-04-17T02:00:00.000Z",
|
|
"lang": "en",
|
|
"value": "VulDB entry created"
|
|
},
|
|
{
|
|
"time": "2024-04-17T07:53:08.000Z",
|
|
"lang": "en",
|
|
"value": "VulDB entry last update"
|
|
}
|
|
],
|
|
"credits": [
|
|
{
|
|
"lang": "en",
|
|
"value": "yhryhryhr_tu (VulDB User)",
|
|
"type": "reporter"
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://vuldb.com/?id.261145",
|
|
"name": "VDB-261145 | Tenda AC500 execCommand formexeCommand stack-based overflow",
|
|
"tags": [
|
|
"vdb-entry",
|
|
"technical-description"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://vuldb.com/?ctiid.261145",
|
|
"name": "VDB-261145 | CTI Indicators (IOB, IOC, IOA)",
|
|
"tags": [
|
|
"signature",
|
|
"permissions-required"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://vuldb.com/?submit.313804",
|
|
"name": "Submit #313804 | Tenda AC500 V2.0.1.9(1307) buffer overflow",
|
|
"tags": [
|
|
"third-party-advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formexeCommand.md",
|
|
"tags": [
|
|
"exploit"
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"adp": [
|
|
{
|
|
"title": "CISA ADP Vulnrichment",
|
|
"metrics": [
|
|
{
|
|
"other": {
|
|
"type": "ssvc",
|
|
"content": {
|
|
"id": "CVE-2024-3909",
|
|
"role": "CISA Coordinator",
|
|
"options": [
|
|
{
|
|
"Exploitation": "none"
|
|
},
|
|
{
|
|
"Automatable": "no"
|
|
},
|
|
{
|
|
"Technical Impact": "partial"
|
|
}
|
|
],
|
|
"version": "2.0.3",
|
|
"timestamp": "2024-04-22T15:10:58.576153Z"
|
|
}
|
|
}
|
|
}
|
|
],
|
|
"affected": [
|
|
{
|
|
"cpes": [
|
|
"cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*"
|
|
],
|
|
"vendor": "tenda",
|
|
"product": "ac500_firmware",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "2.0.1.9\\(1307\\)"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
}
|
|
],
|
|
"providerMetadata": {
|
|
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
|
"shortName": "CISA-ADP",
|
|
"dateUpdated": "2024-06-04T17:31:11.551Z"
|
|
}
|
|
},
|
|
{
|
|
"providerMetadata": {
|
|
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"shortName": "CVE",
|
|
"dateUpdated": "2024-08-01T20:26:57.136Z"
|
|
},
|
|
"title": "CVE Program Container",
|
|
"references": [
|
|
{
|
|
"url": "https://vuldb.com/?id.261145",
|
|
"name": "VDB-261145 | Tenda AC500 execCommand formexeCommand stack-based overflow",
|
|
"tags": [
|
|
"vdb-entry",
|
|
"technical-description",
|
|
"x_transferred"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://vuldb.com/?ctiid.261145",
|
|
"name": "VDB-261145 | CTI Indicators (IOB, IOC, IOA)",
|
|
"tags": [
|
|
"signature",
|
|
"permissions-required",
|
|
"x_transferred"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://vuldb.com/?submit.313804",
|
|
"name": "Submit #313804 | Tenda AC500 V2.0.1.9(1307) buffer overflow",
|
|
"tags": [
|
|
"third-party-advisory",
|
|
"x_transferred"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formexeCommand.md",
|
|
"tags": [
|
|
"exploit",
|
|
"x_transferred"
|
|
]
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
} |