"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"cveMetadata": {
"cveId": "CVE-2024-3264",
"assignerOrgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
"state": "PUBLISHED",
"assignerShortName": "TR-CERT",
"dateReserved": "2024-04-03T12:54:07.773Z",
"datePublished": "2024-06-24T12:45:13.204Z",
"dateUpdated": "2026-06-03T14:16:51.216Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
"shortName": "TR-CERT",
"dateUpdated": "2026-06-03T14:16:51.216Z"
},
"title": "Broken or Risky Cryptographic Algorithm in Mia Technology's Mia-Med Health Aplication",
"problemTypes": [
{
"descriptions": [
{
"lang": "en",
"cweId": "CWE-327",
"description": "CWE-327 Use of a Broken or Risky Cryptographic Algorithm",
"type": "CWE"
}
]
}
],
"impacts": [
{
"capecId": "CAPEC-475",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-475 Signature Spoofing by Improper Validation"
}
]
}
],
"affected": [
{
"vendor": "Mia Technology Inc.",
"product": "Mia-Med Health Aplication",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "1.0.14",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
}
],
"descriptions": [
{
"lang": "en",
"value": "Use of a Broken or Risky Cryptographic Algorithm vulnerability in Mia Technology Inc. Mia-Med Health Aplication allows Signature Spoofing by Improper Validation.\n\nThis issue affects Mia-Med Health Aplication: before 1.0.14.",
"supportingMedia": [
{
"type": "text/html",
"base64": false,
"value": "Use of a Broken or Risky Cryptographic Algorithm vulnerability in Mia Technology Inc. Mia-Med Health Aplication allows Signature Spoofing by Improper Validation.<p>This issue affects Mia-Med Health Aplication: before 1.0.14.</p>"
}
]
}
],
"references": [
{
"url": "https://www.usom.gov.tr/bildirim/tr-24-0765",
"tags": [
"government-resource",
"broken-link"
]
},
{
"url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-24-0765",
"tags": [
"government-resource"
]
}
],
"metrics": [
{
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
],
"cvssV3_1": {
"version": "3.1",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"availabilityImpact": "NONE",
"baseSeverity": "MEDIUM",
"baseScore": 5.3,
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N"
}
}
],
"credits": [
{
"lang": "en",
"value": "Mustafa Anıl YILDIRIM",
"type": "finder"
}
],
"source": {
"defect": [
"TR-24-0765"
],
"advisory": "TR-24-0765",
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
},
"adp": [
{
"affected": [
{
"vendor": "miateknoloji",
"product": "mia-med",
"cpes": [
"cpe:2.3:a:miateknoloji:mia-med:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"versions": [
{
"version": "0",
"status": "affected",
"lessThan": "1.0.14",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2024-06-26T16:49:03.514353Z",
"id": "CVE-2024-3264",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2024-06-26T18:56:37.905Z"
}
},
{
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2024-08-01T20:05:08.373Z"
},
"title": "CVE Program Container",
"references": [
{
"url": "https://www.usom.gov.tr/bildirim/tr-24-0765",
"tags": [
"x_transferred"
]
}
]
}
]
}
}