"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.1",
|
|
"cveMetadata": {
|
|
"cveId": "CVE-2023-41372",
|
|
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
|
|
"state": "PUBLISHED",
|
|
"assignerShortName": "bosch",
|
|
"dateReserved": "2023-10-18T09:35:22.507Z",
|
|
"datePublished": "2023-10-25T14:13:34.827Z",
|
|
"dateUpdated": "2024-09-12T14:28:34.281Z"
|
|
},
|
|
"containers": {
|
|
"cna": {
|
|
"providerMetadata": {
|
|
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
|
|
"shortName": "bosch",
|
|
"dateUpdated": "2023-10-25T14:13:34.827Z"
|
|
},
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "The vulnerability allows an unprivileged (untrusted) third- party application to arbitrary modify the server settings of the Android Client application, inducing it to connect to an attacker - controlled malicious server.This is possible by forging a valid broadcast intent encrypted with a hardcoded RSA key pair"
|
|
}
|
|
],
|
|
"affected": [
|
|
{
|
|
"vendor": "Rexroth",
|
|
"product": "ctrlX HMI Web Panel - WR21 (WR2107)",
|
|
"versions": [
|
|
{
|
|
"version": "all",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"vendor": "Rexroth",
|
|
"product": "ctrlX HMI Web Panel - WR21 (WR2110)",
|
|
"versions": [
|
|
{
|
|
"version": "all",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"vendor": "Rexroth",
|
|
"product": "ctrlX HMI Web Panel - WR21 (WR2115)",
|
|
"versions": [
|
|
{
|
|
"version": "all",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"lang": "en-US",
|
|
"description": "CWE-798 Use of Hard-coded Credentials",
|
|
"cweId": "CWE-798"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
|
|
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
|
|
"tags": [
|
|
"vendor-advisory"
|
|
]
|
|
}
|
|
],
|
|
"metrics": [
|
|
{
|
|
"cvssV3_1": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
|
|
"attackVector": "LOCAL",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "LOW",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 7.8,
|
|
"baseSeverity": "HIGH"
|
|
}
|
|
}
|
|
]
|
|
},
|
|
"adp": [
|
|
{
|
|
"providerMetadata": {
|
|
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"shortName": "CVE",
|
|
"dateUpdated": "2024-08-02T19:01:35.280Z"
|
|
},
|
|
"title": "CVE Program Container",
|
|
"references": [
|
|
{
|
|
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
|
|
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
|
|
"tags": [
|
|
"vendor-advisory",
|
|
"x_transferred"
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"affected": [
|
|
{
|
|
"vendor": "boschrexroth",
|
|
"product": "ctrlx_hmi_web_panel_wr2107",
|
|
"cpes": [
|
|
"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2107:-:*:*:*:*:*:*:*"
|
|
],
|
|
"defaultStatus": "unknown",
|
|
"versions": [
|
|
{
|
|
"version": "0",
|
|
"status": "affected",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"vendor": "boschrexroth",
|
|
"product": "ctrlx_hmi_web_panel_wr2110",
|
|
"cpes": [
|
|
"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2110:-:*:*:*:*:*:*:*"
|
|
],
|
|
"defaultStatus": "unknown",
|
|
"versions": [
|
|
{
|
|
"version": "0",
|
|
"status": "affected",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"vendor": "boschrexroth",
|
|
"product": "ctrlx_hmi_web_panel_wr2115",
|
|
"cpes": [
|
|
"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2115:-:*:*:*:*:*:*:*"
|
|
],
|
|
"defaultStatus": "unknown",
|
|
"versions": [
|
|
{
|
|
"version": "0",
|
|
"status": "affected",
|
|
"lessThan": "*",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"metrics": [
|
|
{
|
|
"other": {
|
|
"type": "ssvc",
|
|
"content": {
|
|
"timestamp": "2024-09-10T18:51:52.995688Z",
|
|
"id": "CVE-2023-41372",
|
|
"options": [
|
|
{
|
|
"Exploitation": "none"
|
|
},
|
|
{
|
|
"Automatable": "no"
|
|
},
|
|
{
|
|
"Technical Impact": "total"
|
|
}
|
|
],
|
|
"role": "CISA Coordinator",
|
|
"version": "2.0.3"
|
|
}
|
|
}
|
|
}
|
|
],
|
|
"title": "CISA ADP Vulnrichment",
|
|
"providerMetadata": {
|
|
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
|
"shortName": "CISA-ADP",
|
|
"dateUpdated": "2024-09-12T14:28:34.281Z"
|
|
}
|
|
}
|
|
]
|
|
}
|
|
} |