Files
vuln-cve/data/2022/4xxx/CVE-2022-4433.json
T

154 lines
5.7 KiB
JSON

{
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"cveMetadata": {
"cveId": "CVE-2022-4433",
"assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"state": "PUBLISHED",
"assignerShortName": "lenovo",
"dateReserved": "2022-12-12T22:16:04.941Z",
"datePublished": "2023-01-05T17:32:48.186Z",
"dateUpdated": "2025-04-10T14:08:23.719Z"
},
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "ThinkPad X13s",
"vendor": "Lenovo",
"versions": [
{
"status": "affected",
"version": "Versions prior to 1.47"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Lenovo thanks BINARLY efiXplorer team for reporting these issues."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A buffer over-read vulnerability was reported in the ThinkPadX13s BIOS LenovoSetupConfigDxe driver that could allow a local attacker with elevated privileges to cause information disclosure."
}
],
"value": "A buffer over-read vulnerability was reported in the ThinkPadX13s BIOS LenovoSetupConfigDxe driver that could allow a local attacker with elevated privileges to cause information disclosure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-126",
"description": "CWE-126",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"shortName": "lenovo",
"dateUpdated": "2023-01-05T17:32:48.186Z"
},
"references": [
{
"url": "https://support.lenovo.com/us/en/product_security/LEN-103709"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
},
"adp": [
{
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2024-08-03T01:41:44.572Z"
},
"title": "CVE Program Container",
"references": [
{
"url": "https://support.lenovo.com/us/en/product_security/LEN-103709",
"tags": [
"x_transferred"
]
}
]
},
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2025-04-10T14:08:15.741463Z",
"id": "CVE-2022-4433",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2025-04-10T14:08:23.719Z"
}
}
]
}
}