"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.2",
|
|
"cveMetadata": {
|
|
"cveId": "CVE-2022-41311",
|
|
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
|
|
"state": "PUBLISHED",
|
|
"assignerShortName": "talos",
|
|
"dateReserved": "2022-09-21T20:50:07.444Z",
|
|
"datePublished": "2023-02-07T16:52:03.034Z",
|
|
"dateUpdated": "2025-11-04T19:14:03.361Z"
|
|
},
|
|
"containers": {
|
|
"cna": {
|
|
"affected": [
|
|
{
|
|
"vendor": "Moxa",
|
|
"product": "SDS-3008 Series Industrial Ethernet Switch",
|
|
"versions": [
|
|
{
|
|
"version": "2.1",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A stored cross-site scripting vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to arbitrary Javascript execution. An attacker can send an HTTP request to trigger this vulnerability.Form field id=\"webLocationMessage_text\" name=\"webLocationMessage_text\""
|
|
}
|
|
],
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"description": "CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')",
|
|
"type": "CWE",
|
|
"cweId": "CWE-79"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"metrics": [
|
|
{
|
|
"cvssV3_0": {
|
|
"version": "3.0",
|
|
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "HIGH",
|
|
"userInteraction": "REQUIRED",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "LOW",
|
|
"integrityImpact": "LOW",
|
|
"availabilityImpact": "LOW",
|
|
"baseScore": 4.3,
|
|
"baseSeverity": "MEDIUM"
|
|
}
|
|
}
|
|
],
|
|
"providerMetadata": {
|
|
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
|
|
"shortName": "talos",
|
|
"dateUpdated": "2023-02-07T16:52:03.034Z"
|
|
},
|
|
"references": [
|
|
{
|
|
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1619",
|
|
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1619"
|
|
},
|
|
{
|
|
"url": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities",
|
|
"name": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities"
|
|
}
|
|
]
|
|
},
|
|
"adp": [
|
|
{
|
|
"title": "CVE Program Container",
|
|
"references": [
|
|
{
|
|
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1619",
|
|
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1619",
|
|
"tags": [
|
|
"x_transferred"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities",
|
|
"name": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities",
|
|
"tags": [
|
|
"x_transferred"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2022-1619"
|
|
}
|
|
],
|
|
"providerMetadata": {
|
|
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"shortName": "CVE",
|
|
"dateUpdated": "2025-11-04T19:14:03.361Z"
|
|
}
|
|
},
|
|
{
|
|
"metrics": [
|
|
{
|
|
"other": {
|
|
"type": "ssvc",
|
|
"content": {
|
|
"timestamp": "2025-03-25T15:36:14.814028Z",
|
|
"id": "CVE-2022-41311",
|
|
"options": [
|
|
{
|
|
"Exploitation": "poc"
|
|
},
|
|
{
|
|
"Automatable": "no"
|
|
},
|
|
{
|
|
"Technical Impact": "partial"
|
|
}
|
|
],
|
|
"role": "CISA Coordinator",
|
|
"version": "2.0.3"
|
|
}
|
|
}
|
|
}
|
|
],
|
|
"title": "CISA ADP Vulnrichment",
|
|
"providerMetadata": {
|
|
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
|
"shortName": "CISA-ADP",
|
|
"dateUpdated": "2025-03-25T15:36:28.809Z"
|
|
}
|
|
}
|
|
]
|
|
}
|
|
} |