"affected": [
|
|
{
|
|
"product": "Parasolid V33.1",
|
|
"vendor": "Siemens",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "All versions < V33.1.262"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "Parasolid V33.1",
|
|
"vendor": "Siemens",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "All versions >= V33.1.262 < V33.1.263"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "Parasolid V34.0",
|
|
"vendor": "Siemens",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "All versions < V34.0.252"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "Parasolid V34.1",
|
|
"vendor": "Siemens",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "All versions < V34.1.242"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "Parasolid V35.0",
|
|
"vendor": "Siemens",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "All versions < V35.0.161"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "Parasolid V35.0",
|
|
"vendor": "Siemens",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "All versions >= V35.0.161 < V35.0.164"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "Simcenter Femap V2022.1",
|
|
"vendor": "Siemens",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "All versions < V2022.1.3"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "Simcenter Femap V2022.2",
|
|
"vendor": "Siemens",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "All versions < V2022.2.2"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17736)"
|
|
}
|
|
],
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"cweId": "CWE-787",
|
|
"description": "CWE-787: Out-of-bounds Write",
|
|
"lang": "en",
|
|
"type": "CWE"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"providerMetadata": {
|
|
"dateUpdated": "2022-09-13T09:41:06.000Z",
|
|
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
|
|
"shortName": "siemens"
|
|
},
|
|
"references": [
|
|
{
|
|
"tags": [
|
|
"x_refsource_MISC"
|
|
],
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
|
|
}
|
|
],
|
|
"x_legacyV4Record": {
|
|
"CVE_data_meta": {
|
|
"ASSIGNER": "productcert@siemens.com",
|
|
"ID": "CVE-2022-39151",
|
|
"STATE": "PUBLIC"
|
|
},
|
|
"affects": {
|
|
"vendor": {
|
|
"vendor_data": [
|
|
{
|
|
"product": {
|
|
"product_data": [
|
|
{
|
|
"product_name": "Parasolid V33.1",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_value": "All versions < V33.1.262"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Parasolid V33.1",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_value": "All versions >= V33.1.262 < V33.1.263"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Parasolid V34.0",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_value": "All versions < V34.0.252"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Parasolid V34.1",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_value": "All versions < V34.1.242"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Parasolid V35.0",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_value": "All versions < V35.0.161"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Parasolid V35.0",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_value": "All versions >= V35.0.161 < V35.0.164"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Simcenter Femap V2022.1",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_value": "All versions < V2022.1.3"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Simcenter Femap V2022.2",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_value": "All versions < V2022.2.2"
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
},
|
|
"vendor_name": "Siemens"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
"data_format": "MITRE",
|
|
"data_type": "CVE",
|
|
"data_version": "4.0",
|
|
"description": {
|
|
"description_data": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17736)"
|
|
}
|
|
]
|
|
},
|
|
"problemtype": {
|
|
"problemtype_data": [
|
|
{
|
|
"description": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "CWE-787: Out-of-bounds Write"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"references": {
|
|
"reference_data": [
|
|
{
|
|
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf",
|
|
"refsource": "MISC",
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
|
|
}
|
|
]
|
|
}
|
|
}
|
|
},
|
|
"adp": [
|
|
{
|
|
"providerMetadata": {
|
|
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"shortName": "CVE",
|
|
"dateUpdated": "2024-08-03T11:10:32.622Z"
|
|
},
|
|
"title": "CVE Program Container",
|
|
"references": [
|
|
{
|
|
"tags": [
|
|
"x_refsource_MISC",
|
|
"x_transferred"
|
|
],
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"metrics": [
|
|
{
|
|
"cvssV3_1": {
|
|
"scope": "UNCHANGED",
|
|
"version": "3.1",
|
|
"baseScore": 7.8,
|
|
"attackVector": "LOCAL",
|
|
"baseSeverity": "HIGH",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
|
|
"integrityImpact": "HIGH",
|
|
"userInteraction": "REQUIRED",
|
|
"attackComplexity": "LOW",
|
|
"availabilityImpact": "HIGH",
|
|
"privilegesRequired": "NONE",
|
|
"confidentialityImpact": "HIGH"
|
|
}
|
|
},
|
|
{
|
|
"other": {
|
|
"type": "ssvc",
|
|
"content": {
|
|
"timestamp": "2025-06-05T18:20:09.285991Z",
|
|
"id": "CVE-2022-39151",
|
|
"options": [
|
|
{
|
|
"Exploitation": "none"
|
|
},
|
|
{
|
|
"Automatable": "no"
|
|
},
|
|
{
|
|
"Technical Impact": "partial"
|
|
}
|
|
],
|
|
"role": "CISA Coordinator",
|
|
"version": "2.0.3"
|
|
}
|
|
}
|
|
}
|
|
],
|
|
"title": "CISA ADP Vulnrichment",
|
|
"providerMetadata": {
|
|
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
|
"shortName": "CISA-ADP",
|
|
"dateUpdated": "2025-06-05T18:20:21.645Z"
|
|
}
|
|
}
|
|
]
|
|
},
|
|
"cveMetadata": {
|
|
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
|
|
"assignerShortName": "siemens",
|
|
"cveId": "CVE-2022-39151",
|
|
"datePublished": "2022-09-13T09:41:06.000Z",
|
|
"dateReserved": "2022-09-01T00:00:00.000Z",
|
|
"dateUpdated": "2025-06-05T18:20:21.645Z",
|
|
"state": "PUBLISHED"
|
|
},
|
|
"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.1"
|
|
} |