Files
vuln-cve/data/2022/2xxx/CVE-2022-2988.json
T

145 lines
5.7 KiB
JSON
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
{
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"cveMetadata": {
"state": "PUBLISHED",
"cveId": "CVE-2022-2988",
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"dateUpdated": "2025-02-05T20:08:49.920Z",
"dateReserved": "2022-08-25T00:00:00.000Z",
"datePublished": "2023-01-30T00:00:00.000Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider",
"dateUpdated": "2023-02-03T00:00:00.000Z"
},
"descriptions": [
{
"lang": "en",
"value": "A CWE-787: Out-of-bounds Write vulnerability exists that could cause sensitive information leakage when accessing a malicious web page from the commissioning software. Affected Products: SoMachine HVAC (Versions prior to V2.1.0), EcoStruxure Machine Expert – HVAC (Versions prior to V1.4.0)"
}
],
"affected": [
{
"vendor": "Schneider Electric",
"product": "SoMachine HVAC",
"versions": [
{
"version": "All",
"status": "affected",
"lessThan": "V2.1.0",
"versionType": "custom"
}
]
},
{
"vendor": "Schneider Electric",
"product": "EcoStruxure Machine Expert – HVAC",
"versions": [
{
"version": "All",
"status": "affected",
"lessThan": "V1.4.0",
"versionType": "custom"
}
]
}
],
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-010-01_EcoStruxure_Machine_Expert_Machine_HVAC_Security_Notification.pdf"
}
],
"metrics": [
{
"cvssV3_1": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"type": "CWE",
"lang": "en",
"description": "CWE-787 Out-of-bounds Write",
"cweId": "CWE-787"
}
]
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"source": {
"discovery": "UNKNOWN"
}
},
"adp": [
{
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2024-08-03T00:53:00.478Z"
},
"title": "CVE Program Container",
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-010-01_EcoStruxure_Machine_Expert_Machine_HVAC_Security_Notification.pdf",
"tags": [
"x_transferred"
]
}
]
},
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2025-02-05T19:50:42.632868Z",
"id": "CVE-2022-2988",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2025-02-05T20:08:49.920Z"
}
}
]
}
}