"containers": {
|
||
"cna": {
|
||
"affected": [
|
||
{
|
||
"product": "SoftMaster",
|
||
"vendor": "Honeywell",
|
||
"versions": [
|
||
{
|
||
"status": "affected",
|
||
"version": "4.51"
|
||
}
|
||
]
|
||
}
|
||
],
|
||
"credits": [
|
||
{
|
||
"lang": "en",
|
||
"value": "Noam Moshe of Claroty Research reported these vulnerabilities to Honeywell."
|
||
}
|
||
],
|
||
"datePublic": "2022-09-13T00:00:00.000Z",
|
||
"descriptions": [
|
||
{
|
||
"lang": "en",
|
||
"value": "If an attacker manages to trick a valid user into loading a malicious DLL, the attacker may be able to achieve code execution in Honeywell SoftMaster version 4.51 application’s context and permissions."
|
||
}
|
||
],
|
||
"metrics": [
|
||
{
|
||
"cvssV3_1": {
|
||
"attackComplexity": "LOW",
|
||
"attackVector": "NETWORK",
|
||
"availabilityImpact": "HIGH",
|
||
"baseScore": 8.8,
|
||
"baseSeverity": "HIGH",
|
||
"confidentialityImpact": "HIGH",
|
||
"integrityImpact": "HIGH",
|
||
"privilegesRequired": "NONE",
|
||
"scope": "UNCHANGED",
|
||
"userInteraction": "REQUIRED",
|
||
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
|
||
"version": "3.1"
|
||
}
|
||
}
|
||
],
|
||
"problemTypes": [
|
||
{
|
||
"descriptions": [
|
||
{
|
||
"cweId": "CWE-427",
|
||
"description": "CWE-427: Uncontrolled Search Path Element",
|
||
"lang": "en",
|
||
"type": "CWE"
|
||
}
|
||
]
|
||
}
|
||
],
|
||
"providerMetadata": {
|
||
"dateUpdated": "2022-09-16T20:18:42.000Z",
|
||
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
|
||
"shortName": "icscert"
|
||
},
|
||
"references": [
|
||
{
|
||
"tags": [
|
||
"x_refsource_CONFIRM"
|
||
],
|
||
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-256-02"
|
||
},
|
||
{
|
||
"tags": [
|
||
"x_refsource_CONFIRM"
|
||
],
|
||
"url": "https://www.security.honeywell.com/-/media/Security/Resources/PDF/Product-Warranty/Security_Notification_SN_2019-09-13-02_V4-pdf.pdf"
|
||
}
|
||
],
|
||
"solutions": [
|
||
{
|
||
"lang": "en",
|
||
"value": "Honeywell has released firmware update packages for the affected products on their website.\nMore information can be found in the Honeywell Security Notification SN2022-08-31 01 SoftMaster-R4.7"
|
||
}
|
||
],
|
||
"source": {
|
||
"discovery": "EXTERNAL"
|
||
},
|
||
"title": "Honeywell SoftMaster Uncontrolled Search Path Element",
|
||
"workarounds": [
|
||
{
|
||
"lang": "en",
|
||
"value": "Honeywell recommends users with potentially affected products take the following steps to protect themselves:\nUpdate firmware of vulnerable and affected devices.\nIsolate systems from the internet or create additional layers of defense to their system from the internet by placing the affected hardware behind a firewall or into a demilitarized zone (DMZ).\nIf remote connections to the network are required, then users should consider using a VPN or other means to ensure secure remote connections into the network where the device is located.\n\nMore information can be found in the Honeywell Security Notification SN2022-08-31 01 SoftMaster-R4.7"
|
||
}
|
||
],
|
||
"x_generator": {
|
||
"engine": "Vulnogram 0.0.9"
|
||
},
|
||
"x_legacyV4Record": {
|
||
"CVE_data_meta": {
|
||
"ASSIGNER": "ics-cert@hq.dhs.gov",
|
||
"DATE_PUBLIC": "2022-09-13T21:40:00.000Z",
|
||
"ID": "CVE-2022-2333",
|
||
"STATE": "PUBLIC",
|
||
"TITLE": "Honeywell SoftMaster Uncontrolled Search Path Element"
|
||
},
|
||
"affects": {
|
||
"vendor": {
|
||
"vendor_data": [
|
||
{
|
||
"product": {
|
||
"product_data": [
|
||
{
|
||
"product_name": "SoftMaster",
|
||
"version": {
|
||
"version_data": [
|
||
{
|
||
"version_affected": "=",
|
||
"version_value": "4.51"
|
||
}
|
||
]
|
||
}
|
||
}
|
||
]
|
||
},
|
||
"vendor_name": "Honeywell"
|
||
}
|
||
]
|
||
}
|
||
},
|
||
"credit": [
|
||
{
|
||
"lang": "eng",
|
||
"value": "Noam Moshe of Claroty Research reported these vulnerabilities to Honeywell."
|
||
}
|
||
],
|
||
"data_format": "MITRE",
|
||
"data_type": "CVE",
|
||
"data_version": "4.0",
|
||
"description": {
|
||
"description_data": [
|
||
{
|
||
"lang": "eng",
|
||
"value": "If an attacker manages to trick a valid user into loading a malicious DLL, the attacker may be able to achieve code execution in Honeywell SoftMaster version 4.51 application’s context and permissions."
|
||
}
|
||
]
|
||
},
|
||
"generator": {
|
||
"engine": "Vulnogram 0.0.9"
|
||
},
|
||
"impact": {
|
||
"cvss": {
|
||
"attackComplexity": "LOW",
|
||
"attackVector": "NETWORK",
|
||
"availabilityImpact": "HIGH",
|
||
"baseScore": 8.8,
|
||
"baseSeverity": "HIGH",
|
||
"confidentialityImpact": "HIGH",
|
||
"integrityImpact": "HIGH",
|
||
"privilegesRequired": "NONE",
|
||
"scope": "UNCHANGED",
|
||
"userInteraction": "REQUIRED",
|
||
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
|
||
"version": "3.1"
|
||
}
|
||
},
|
||
"problemtype": {
|
||
"problemtype_data": [
|
||
{
|
||
"description": [
|
||
{
|
||
"lang": "eng",
|
||
"value": "CWE-427: Uncontrolled Search Path Element"
|
||
}
|
||
]
|
||
}
|
||
]
|
||
},
|
||
"references": {
|
||
"reference_data": [
|
||
{
|
||
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-256-02",
|
||
"refsource": "CONFIRM",
|
||
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-256-02"
|
||
},
|
||
{
|
||
"name": "https://www.security.honeywell.com/-/media/Security/Resources/PDF/Product-Warranty/Security_Notification_SN_2019-09-13-02_V4-pdf.pdf",
|
||
"refsource": "CONFIRM",
|
||
"url": "https://www.security.honeywell.com/-/media/Security/Resources/PDF/Product-Warranty/Security_Notification_SN_2019-09-13-02_V4-pdf.pdf"
|
||
}
|
||
]
|
||
},
|
||
"solution": [
|
||
{
|
||
"lang": "en",
|
||
"value": "Honeywell has released firmware update packages for the affected products on their website.\nMore information can be found in the Honeywell Security Notification SN2022-08-31 01 SoftMaster-R4.7"
|
||
}
|
||
],
|
||
"source": {
|
||
"discovery": "EXTERNAL"
|
||
},
|
||
"work_around": [
|
||
{
|
||
"lang": "en",
|
||
"value": "Honeywell recommends users with potentially affected products take the following steps to protect themselves:\nUpdate firmware of vulnerable and affected devices.\nIsolate systems from the internet or create additional layers of defense to their system from the internet by placing the affected hardware behind a firewall or into a demilitarized zone (DMZ).\nIf remote connections to the network are required, then users should consider using a VPN or other means to ensure secure remote connections into the network where the device is located.\n\nMore information can be found in the Honeywell Security Notification SN2022-08-31 01 SoftMaster-R4.7"
|
||
}
|
||
]
|
||
}
|
||
},
|
||
"adp": [
|
||
{
|
||
"providerMetadata": {
|
||
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
|
||
"shortName": "CVE",
|
||
"dateUpdated": "2024-08-03T00:32:09.614Z"
|
||
},
|
||
"title": "CVE Program Container",
|
||
"references": [
|
||
{
|
||
"tags": [
|
||
"x_refsource_CONFIRM",
|
||
"x_transferred"
|
||
],
|
||
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-256-02"
|
||
},
|
||
{
|
||
"tags": [
|
||
"x_refsource_CONFIRM",
|
||
"x_transferred"
|
||
],
|
||
"url": "https://www.security.honeywell.com/-/media/Security/Resources/PDF/Product-Warranty/Security_Notification_SN_2019-09-13-02_V4-pdf.pdf"
|
||
}
|
||
]
|
||
},
|
||
{
|
||
"metrics": [
|
||
{
|
||
"other": {
|
||
"type": "ssvc",
|
||
"content": {
|
||
"timestamp": "2025-04-16T17:27:13.488681Z",
|
||
"id": "CVE-2022-2333",
|
||
"options": [
|
||
{
|
||
"Exploitation": "none"
|
||
},
|
||
{
|
||
"Automatable": "no"
|
||
},
|
||
{
|
||
"Technical Impact": "total"
|
||
}
|
||
],
|
||
"role": "CISA Coordinator",
|
||
"version": "2.0.3"
|
||
}
|
||
}
|
||
}
|
||
],
|
||
"title": "CISA ADP Vulnrichment",
|
||
"providerMetadata": {
|
||
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
||
"shortName": "CISA-ADP",
|
||
"dateUpdated": "2025-04-16T17:47:27.339Z"
|
||
}
|
||
}
|
||
]
|
||
},
|
||
"cveMetadata": {
|
||
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
|
||
"assignerShortName": "icscert",
|
||
"cveId": "CVE-2022-2333",
|
||
"datePublished": "2022-09-16T20:18:42.695Z",
|
||
"dateReserved": "2022-07-06T00:00:00.000Z",
|
||
"dateUpdated": "2025-04-16T17:47:27.339Z",
|
||
"state": "PUBLISHED"
|
||
},
|
||
"dataType": "CVE_RECORD",
|
||
"dataVersion": "5.1"
|
||
} |