Files
vuln-cve/data/2021/31xxx/CVE-2021-31882.json
T

140 lines
5.3 KiB
JSON

{
"containers": {
"cna": {
"providerMetadata": {
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens",
"dateUpdated": "2025-03-11T09:47:42.320Z"
},
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303). The DHCP client application does not validate the length of the Domain Name Server IP option(s) (0x06) when processing DHCP ACK packets. This may lead to Denial-of-Service conditions. (FSMD-2021-0011)"
}
],
"affected": [
{
"vendor": "Siemens",
"product": "Capital Embedded AR Classic 431-422",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Capital Embedded AR Classic R20-11",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2303",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
],
"metrics": [
{
"cvssV3_1": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"baseScore": 6.5,
"baseSeverity": "MEDIUM"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"lang": "en",
"cweId": "CWE-119",
"description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
"type": "CWE"
}
]
}
],
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-114589.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-044112.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-620288.html"
}
]
},
"adp": [
{
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2024-08-03T23:10:30.782Z"
},
"title": "CVE Program Container",
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
}
]
}
]
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-31882",
"datePublished": "2021-11-09T11:31:55.000Z",
"dateReserved": "2021-04-29T00:00:00.000Z",
"dateUpdated": "2025-03-11T09:47:42.320Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}