401 lines
19 KiB
JSON
401 lines
19 KiB
JSON
{
|
|
"containers": {
|
|
"cna": {
|
|
"affected": [
|
|
{
|
|
"product": "Opcenter Execution Discrete",
|
|
"vendor": "Siemens",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "All versions < V3.2"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "Opcenter Execution Foundation",
|
|
"vendor": "Siemens",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "All versions < V3.2"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "Opcenter Execution Process",
|
|
"vendor": "Siemens",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "All versions < V3.2"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "Opcenter Intelligence",
|
|
"vendor": "Siemens",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "All versions < V3.3"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "Opcenter Quality",
|
|
"vendor": "Siemens",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "All versions < V11.3"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "Opcenter RD&L",
|
|
"vendor": "Siemens",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "V8.0"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "SIMATIC Notifier Server for Windows",
|
|
"vendor": "Siemens",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "All versions"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "SIMATIC PCS neo",
|
|
"vendor": "Siemens",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "All versions < V3.0 SP1"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "SIMATIC STEP 7 (TIA Portal) V15",
|
|
"vendor": "Siemens",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "All versions < V15.1 Update 5"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "SIMATIC STEP 7 (TIA Portal) V16",
|
|
"vendor": "Siemens",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "All versions < V16 Update 2"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "SIMOCODE ES V15.1",
|
|
"vendor": "Siemens",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "All versions < V15.1 Update 4"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "SIMOCODE ES V16",
|
|
"vendor": "Siemens",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "All versions < V16 Update 1"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "Soft Starter ES V15.1",
|
|
"vendor": "Siemens",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "All versions < V15.1 Update 3"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "Soft Starter ES V16",
|
|
"vendor": "Siemens",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "All versions < V16 Update 1"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted. This could allow a local attacker with administrative privileges to execute code with SYSTEM level privileges."
|
|
}
|
|
],
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"cweId": "CWE-428",
|
|
"description": "CWE-428: Unquoted Search Path or Element",
|
|
"lang": "en",
|
|
"type": "CWE"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"providerMetadata": {
|
|
"dateUpdated": "2022-08-10T11:16:47.000Z",
|
|
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
|
|
"shortName": "siemens"
|
|
},
|
|
"references": [
|
|
{
|
|
"tags": [
|
|
"x_refsource_MISC"
|
|
],
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf"
|
|
}
|
|
],
|
|
"x_legacyV4Record": {
|
|
"CVE_data_meta": {
|
|
"ASSIGNER": "productcert@siemens.com",
|
|
"ID": "CVE-2020-7581",
|
|
"STATE": "PUBLIC"
|
|
},
|
|
"affects": {
|
|
"vendor": {
|
|
"vendor_data": [
|
|
{
|
|
"product": {
|
|
"product_data": [
|
|
{
|
|
"product_name": "Opcenter Execution Discrete",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_value": "All versions < V3.2"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Opcenter Execution Foundation",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_value": "All versions < V3.2"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Opcenter Execution Process",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_value": "All versions < V3.2"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Opcenter Intelligence",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_value": "All versions < V3.3"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Opcenter Quality",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_value": "All versions < V11.3"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Opcenter RD&L",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_value": "V8.0"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "SIMATIC Notifier Server for Windows",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_value": "All versions"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "SIMATIC PCS neo",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_value": "All versions < V3.0 SP1"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "SIMATIC STEP 7 (TIA Portal) V15",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_value": "All versions < V15.1 Update 5"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "SIMATIC STEP 7 (TIA Portal) V16",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_value": "All versions < V16 Update 2"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "SIMOCODE ES V15.1",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_value": "All versions < V15.1 Update 4"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "SIMOCODE ES V16",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_value": "All versions < V16 Update 1"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Soft Starter ES V15.1",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_value": "All versions < V15.1 Update 3"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Soft Starter ES V16",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_value": "All versions < V16 Update 1"
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
},
|
|
"vendor_name": "Siemens"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
"data_format": "MITRE",
|
|
"data_type": "CVE",
|
|
"data_version": "4.0",
|
|
"description": {
|
|
"description_data": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted. This could allow a local attacker with administrative privileges to execute code with SYSTEM level privileges."
|
|
}
|
|
]
|
|
},
|
|
"problemtype": {
|
|
"problemtype_data": [
|
|
{
|
|
"description": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "CWE-428: Unquoted Search Path or Element"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"references": {
|
|
"reference_data": [
|
|
{
|
|
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf",
|
|
"refsource": "MISC",
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf"
|
|
}
|
|
]
|
|
}
|
|
}
|
|
},
|
|
"adp": [
|
|
{
|
|
"providerMetadata": {
|
|
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"shortName": "CVE",
|
|
"dateUpdated": "2024-08-04T09:33:19.617Z"
|
|
},
|
|
"title": "CVE Program Container",
|
|
"references": [
|
|
{
|
|
"tags": [
|
|
"x_refsource_MISC",
|
|
"x_transferred"
|
|
],
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"cveMetadata": {
|
|
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
|
|
"assignerShortName": "siemens",
|
|
"cveId": "CVE-2020-7581",
|
|
"datePublished": "2020-07-14T13:18:05.000Z",
|
|
"dateReserved": "2020-01-21T00:00:00.000Z",
|
|
"dateUpdated": "2024-08-04T09:33:19.617Z",
|
|
"state": "PUBLISHED"
|
|
},
|
|
"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.1"
|
|
} |