"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.1",
|
|
"cveMetadata": {
|
|
"state": "PUBLISHED",
|
|
"cveId": "CVE-2020-7580",
|
|
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
|
|
"assignerShortName": "siemens",
|
|
"dateUpdated": "2024-08-04T09:33:19.492Z",
|
|
"dateReserved": "2020-01-21T00:00:00.000Z",
|
|
"datePublished": "2020-06-10T00:00:00.000Z"
|
|
},
|
|
"containers": {
|
|
"cna": {
|
|
"providerMetadata": {
|
|
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
|
|
"shortName": "siemens",
|
|
"dateUpdated": "2022-12-13T00:00:00.000Z"
|
|
},
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions < V17), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC STEP 7 V5 (All versions < V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions < V3.16 P018), SIMATIC WinCC OA V3.17 (All versions < V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER (All Versions < V5.4 HF2), SINAMICS Startdrive (All Versions < V16 Update 3), SINEC NMS (All versions < V1.0 SP2), SINEMA Server (All versions < V14 SP3), SINUMERIK ONE virtual (All Versions < V6.14), SINUMERIK Operate (All Versions < V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges."
|
|
}
|
|
],
|
|
"affected": [
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC Automation Tool",
|
|
"versions": [
|
|
{
|
|
"version": "All versions < V4 SP2",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC NET PC Software V14",
|
|
"versions": [
|
|
{
|
|
"version": "All versions < V14 SP1 Update 14",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC NET PC Software V15",
|
|
"versions": [
|
|
{
|
|
"version": "All versions",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC NET PC Software V16",
|
|
"versions": [
|
|
{
|
|
"version": "All versions < V16 Upd3",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC PCS neo",
|
|
"versions": [
|
|
{
|
|
"version": "All versions < V3.0 SP1",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC ProSave",
|
|
"versions": [
|
|
{
|
|
"version": "All versions < V17",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1500 Software Controller",
|
|
"versions": [
|
|
{
|
|
"version": "All versions < V21.8",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC STEP 7 (TIA Portal) V13",
|
|
"versions": [
|
|
{
|
|
"version": "All versions < V13 SP2 Update 4",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC STEP 7 (TIA Portal) V14",
|
|
"versions": [
|
|
{
|
|
"version": "All versions < V14 SP1 Update 10",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC STEP 7 (TIA Portal) V15",
|
|
"versions": [
|
|
{
|
|
"version": "All versions < V15.1 Update 5",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC STEP 7 (TIA Portal) V16",
|
|
"versions": [
|
|
{
|
|
"version": "All versions < V16 Update 2",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC STEP 7 V5",
|
|
"versions": [
|
|
{
|
|
"version": "All versions < V5.6 SP2 HF3",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC WinCC OA V3.16",
|
|
"versions": [
|
|
{
|
|
"version": "All versions < V3.16 P018",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC WinCC OA V3.17",
|
|
"versions": [
|
|
{
|
|
"version": "All versions < V3.17 P003",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC WinCC Runtime Advanced",
|
|
"versions": [
|
|
{
|
|
"version": "All versions < V16 Update 2",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC WinCC Runtime Professional V13",
|
|
"versions": [
|
|
{
|
|
"version": "All versions < V13 SP2 Update 4",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC WinCC Runtime Professional V14",
|
|
"versions": [
|
|
{
|
|
"version": "All versions < V14 SP1 Update 10",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC WinCC Runtime Professional V15",
|
|
"versions": [
|
|
{
|
|
"version": "All versions < V15.1 Update 5",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC WinCC Runtime Professional V16",
|
|
"versions": [
|
|
{
|
|
"version": "All versions < V16 Update 2",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC WinCC V7.4",
|
|
"versions": [
|
|
{
|
|
"version": "All versions < V7.4 SP1 Update 14",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC WinCC V7.5",
|
|
"versions": [
|
|
{
|
|
"version": "All versions < V7.5 SP1 Update 3",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SINAMICS STARTER",
|
|
"versions": [
|
|
{
|
|
"version": "All Versions < V5.4 HF2",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SINAMICS Startdrive",
|
|
"versions": [
|
|
{
|
|
"version": "All Versions < V16 Update 3",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SINEC NMS",
|
|
"versions": [
|
|
{
|
|
"version": "All versions < V1.0 SP2",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SINEMA Server",
|
|
"versions": [
|
|
{
|
|
"version": "All versions < V14 SP3",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SINUMERIK ONE virtual",
|
|
"versions": [
|
|
{
|
|
"version": "All Versions < V6.14",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SINUMERIK Operate",
|
|
"versions": [
|
|
{
|
|
"version": "All Versions < V6.14",
|
|
"status": "affected"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf"
|
|
},
|
|
{
|
|
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04"
|
|
}
|
|
],
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"type": "CWE",
|
|
"lang": "en",
|
|
"description": "CWE-428: Unquoted Search Path or Element",
|
|
"cweId": "CWE-428"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"adp": [
|
|
{
|
|
"providerMetadata": {
|
|
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"shortName": "CVE",
|
|
"dateUpdated": "2024-08-04T09:33:19.492Z"
|
|
},
|
|
"title": "CVE Program Container",
|
|
"references": [
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf",
|
|
"tags": [
|
|
"x_transferred"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04",
|
|
"tags": [
|
|
"x_transferred"
|
|
]
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
} |