"containers": {
|
|
"cna": {
|
|
"affected": [
|
|
{
|
|
"product": "CW Configurator",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 1.010L",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "FR Configurator2",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 1.22Y",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "GX Works2",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 1.595V",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "GX Works3",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 1.063R",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "MELSOFT iQ AppPortal",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 1.17T",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "MELSOFT Navigator",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version2.70Y",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "MI Configurator",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "All Versions"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "MR Configurator2",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 1.110Q",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "MT Works2",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Versions 1.156N",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "MX Component",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Version 4.20W",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "RT ToolBox3",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Versions 1.70Y",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"product": "MELSEC iQ-R Series Motion Module",
|
|
"vendor": "Mitsubishi Electric",
|
|
"versions": [
|
|
{
|
|
"lessThanOrEqual": "Versions 10",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"credits": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Mashav Sapir of Claroty reported this vulnerability to CISA"
|
|
}
|
|
],
|
|
"datePublic": "2020-07-30T00:00:00.000Z",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code."
|
|
}
|
|
],
|
|
"metrics": [
|
|
{
|
|
"cvssV3_1": {
|
|
"attackComplexity": "HIGH",
|
|
"attackVector": "NETWORK",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 8.3,
|
|
"baseSeverity": "HIGH",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"privilegesRequired": "NONE",
|
|
"scope": "CHANGED",
|
|
"userInteraction": "REQUIRED",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
|
|
"version": "3.1"
|
|
}
|
|
}
|
|
],
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"cweId": "CWE-22",
|
|
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')",
|
|
"lang": "en",
|
|
"type": "CWE"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"providerMetadata": {
|
|
"dateUpdated": "2022-02-18T23:17:23.000Z",
|
|
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
|
|
"shortName": "icscert"
|
|
},
|
|
"references": [
|
|
{
|
|
"tags": [
|
|
"x_refsource_MISC"
|
|
],
|
|
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03"
|
|
},
|
|
{
|
|
"tags": [
|
|
"x_refsource_MISC"
|
|
],
|
|
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf"
|
|
},
|
|
{
|
|
"tags": [
|
|
"x_refsource_MISC"
|
|
],
|
|
"url": "https://jvn.jp/vu/JVNVU90224831/"
|
|
}
|
|
],
|
|
"source": {
|
|
"advisory": "ICSA-20-212-03",
|
|
"discovery": "UNKNOWN"
|
|
},
|
|
"title": "Mitsubishi Electric Factory Automation Products Path Traversal",
|
|
"x_generator": {
|
|
"engine": "Vulnogram 0.0.9"
|
|
},
|
|
"x_legacyV4Record": {
|
|
"CVE_data_meta": {
|
|
"ASSIGNER": "ics-cert@hq.dhs.gov",
|
|
"DATE_PUBLIC": "2020-07-30T16:50:00.000Z",
|
|
"ID": "CVE-2020-14523",
|
|
"STATE": "PUBLIC",
|
|
"TITLE": "Mitsubishi Electric Factory Automation Products Path Traversal"
|
|
},
|
|
"affects": {
|
|
"vendor": {
|
|
"vendor_data": [
|
|
{
|
|
"product": {
|
|
"product_data": [
|
|
{
|
|
"product_name": "CW Configurator",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<=",
|
|
"version_value": "Version 1.010L"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "FR Configurator2",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<=",
|
|
"version_value": "Version 1.22Y"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "GX Works2",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<=",
|
|
"version_value": "Version 1.595V"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "GX Works3",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<=",
|
|
"version_value": "Version 1.063R"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "MELSOFT iQ AppPortal",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<=",
|
|
"version_value": "Version 1.17T"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "MELSOFT Navigator",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<=",
|
|
"version_value": "Version2.70Y"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "MI Configurator",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "=",
|
|
"version_value": "All Versions"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "MR Configurator2",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<=",
|
|
"version_value": "Version 1.110Q"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "MT Works2",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<=",
|
|
"version_value": "Versions 1.156N"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "MX Component",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<=",
|
|
"version_value": "Version 4.20W"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "RT ToolBox3",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<=",
|
|
"version_value": "Versions 1.70Y"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "MELSEC iQ-R Series Motion Module",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<=",
|
|
"version_value": "Versions 10"
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
},
|
|
"vendor_name": "Mitsubishi Electric"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
"credit": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "Mashav Sapir of Claroty reported this vulnerability to CISA"
|
|
}
|
|
],
|
|
"data_format": "MITRE",
|
|
"data_type": "CVE",
|
|
"data_version": "4.0",
|
|
"description": {
|
|
"description_data": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code."
|
|
}
|
|
]
|
|
},
|
|
"generator": {
|
|
"engine": "Vulnogram 0.0.9"
|
|
},
|
|
"impact": {
|
|
"cvss": {
|
|
"attackComplexity": "HIGH",
|
|
"attackVector": "NETWORK",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 8.3,
|
|
"baseSeverity": "HIGH",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"privilegesRequired": "NONE",
|
|
"scope": "CHANGED",
|
|
"userInteraction": "REQUIRED",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
|
|
"version": "3.1"
|
|
}
|
|
},
|
|
"problemtype": {
|
|
"problemtype_data": [
|
|
{
|
|
"description": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"references": {
|
|
"reference_data": [
|
|
{
|
|
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03",
|
|
"refsource": "MISC",
|
|
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03"
|
|
},
|
|
{
|
|
"name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf",
|
|
"refsource": "MISC",
|
|
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf"
|
|
},
|
|
{
|
|
"name": "https://jvn.jp/vu/JVNVU90224831/",
|
|
"refsource": "MISC",
|
|
"url": "https://jvn.jp/vu/JVNVU90224831/"
|
|
}
|
|
]
|
|
},
|
|
"solution": [
|
|
{
|
|
"lang": "en"
|
|
}
|
|
],
|
|
"source": {
|
|
"advisory": "ICSA-20-212-03",
|
|
"discovery": "UNKNOWN"
|
|
}
|
|
}
|
|
},
|
|
"adp": [
|
|
{
|
|
"providerMetadata": {
|
|
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"shortName": "CVE",
|
|
"dateUpdated": "2024-08-04T12:46:34.640Z"
|
|
},
|
|
"title": "CVE Program Container",
|
|
"references": [
|
|
{
|
|
"tags": [
|
|
"x_refsource_MISC",
|
|
"x_transferred"
|
|
],
|
|
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03"
|
|
},
|
|
{
|
|
"tags": [
|
|
"x_refsource_MISC",
|
|
"x_transferred"
|
|
],
|
|
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf"
|
|
},
|
|
{
|
|
"tags": [
|
|
"x_refsource_MISC",
|
|
"x_transferred"
|
|
],
|
|
"url": "https://jvn.jp/vu/JVNVU90224831/"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"metrics": [
|
|
{
|
|
"other": {
|
|
"type": "ssvc",
|
|
"content": {
|
|
"timestamp": "2025-04-16T17:31:26.782063Z",
|
|
"id": "CVE-2020-14523",
|
|
"options": [
|
|
{
|
|
"Exploitation": "none"
|
|
},
|
|
{
|
|
"Automatable": "no"
|
|
},
|
|
{
|
|
"Technical Impact": "total"
|
|
}
|
|
],
|
|
"role": "CISA Coordinator",
|
|
"version": "2.0.3"
|
|
}
|
|
}
|
|
}
|
|
],
|
|
"title": "CISA ADP Vulnrichment",
|
|
"providerMetadata": {
|
|
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
|
"shortName": "CISA-ADP",
|
|
"dateUpdated": "2025-04-16T18:01:22.616Z"
|
|
}
|
|
}
|
|
]
|
|
},
|
|
"cveMetadata": {
|
|
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
|
|
"assignerShortName": "icscert",
|
|
"cveId": "CVE-2020-14523",
|
|
"datePublished": "2022-02-11T17:40:29.187Z",
|
|
"dateReserved": "2020-06-19T00:00:00.000Z",
|
|
"dateUpdated": "2025-04-16T18:01:22.616Z",
|
|
"state": "PUBLISHED"
|
|
},
|
|
"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.1"
|
|
} |