Files
vuln-cve/data/2019/25xxx/CVE-2019-25720.json
T

227 lines
9.3 KiB
JSON

{
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"cveMetadata": {
"cveId": "CVE-2019-25720",
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"state": "PUBLISHED",
"assignerShortName": "VulnCheck",
"dateReserved": "2026-06-02T14:22:01.500Z",
"datePublished": "2026-06-03T16:56:29.683Z",
"dateUpdated": "2026-06-03T17:44:47.456Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck",
"dateUpdated": "2026-06-03T16:56:29.683Z"
},
"title": "Dräger SC Monitoring Devices DoS via Malformed Network Packet",
"datePublic": "2019-11-21T00:00:00.000Z",
"problemTypes": [
{
"descriptions": [
{
"lang": "en",
"cweId": "CWE-1286",
"description": "CWE-1286 Improper Validation of Syntactic Correctness of Input",
"type": "CWE"
}
]
}
],
"affected": [
{
"vendor": "Dräger",
"product": "SC 6002XL",
"versions": [
{
"status": "affected",
"version": "SC 6002XL",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Dräger",
"product": "SC6802XL",
"versions": [
{
"status": "affected",
"version": "SC6802XL",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Dräger",
"product": "SC 7000",
"versions": [
{
"status": "affected",
"version": "SC 7000",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Dräger",
"product": "SC8000",
"versions": [
{
"status": "affected",
"version": "SC8000",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Dräger",
"product": "SC90000 XL",
"versions": [
{
"status": "affected",
"version": "SC90000 XL",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
],
"descriptions": [
{
"lang": "en",
"value": "Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL) contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send such malformed packets to disrupt patient monitoring until the device falls back to default configuration and loses network connectivity.",
"supportingMedia": [
{
"type": "text/html",
"base64": false,
"value": "<p>Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL) contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send such malformed packets to disrupt patient monitoring until the device falls back to default configuration and loses network connectivity.</p>"
}
]
}
],
"references": [
{
"url": "https://static.draeger.com/security/download/2019-11-27-Draeger-SC7000-SC9000-security-advisory-update-v1-5.pdf",
"tags": [
"vendor-advisory"
]
},
{
"url": "https://www.vulncheck.com/advisories/dr-ger-sc-monitoring-devices-dos-via-malformed-network-packet",
"tags": [
"third-party-advisory"
]
}
],
"metrics": [
{
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
],
"cvssV4_0": {
"attackVector": "ADJACENT",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"vulnConfidentialityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"subIntegrityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"subAvailabilityImpact": "NONE",
"exploitMaturity": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"version": "4.0",
"baseSeverity": "HIGH",
"baseScore": 7.1,
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N"
}
},
{
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
],
"cvssV3_1": {
"version": "3.1",
"attackVector": "ADJACENT_NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "HIGH",
"baseSeverity": "MEDIUM",
"baseScore": 6.5,
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
}
],
"credits": [
{
"lang": "en",
"value": "Jeroen Slobbe and Max Grim",
"type": "finder"
}
],
"source": {
"discovery": "EXTERNAL"
}
},
"adp": [
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2026-06-03T17:44:08.218138Z",
"id": "CVE-2019-25720",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2026-06-03T17:44:47.456Z"
}
}
]
}
}