Files
vuln-cve/data/2019/20xxx/CVE-2019-20464.json
T

166 lines
6.6 KiB
JSON

{
"dataType": "CVE_RECORD",
"cveMetadata": {
"state": "PUBLISHED",
"cveId": "CVE-2019-20464",
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"dateUpdated": "2024-08-05T02:39:10.022Z",
"dateReserved": "2020-02-17T00:00:00.000Z",
"datePublished": "2021-04-02T15:32:59.000Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre",
"dateUpdated": "2024-07-30T00:07:44.152Z"
},
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on Sannce Smart HD Wifi Security Camera EAN 2 950004 595317 devices. By default, a mobile application is used to stream over UDP. However, the device offers many more services that also enable streaming. Although the service used by the mobile application requires a password, the other streaming services do not. By initiating communication on the RTSP port, an attacker can obtain access to the video feed without authenticating."
}
],
"affected": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"version": "n/a",
"status": "affected"
}
]
}
],
"references": [
{
"url": "https://www.eurofins-cybersecurity.com/news/connected-devices-baby-monitors-part-2/"
},
{
"name": "20240729 Bunch of IoT CVEs",
"tags": [
"mailing-list"
],
"url": "http://seclists.org/fulldisclosure/2024/Jul/14"
}
],
"problemTypes": [
{
"descriptions": [
{
"type": "text",
"lang": "en",
"description": "n/a"
}
]
}
],
"datePublic": "2021-03-30T00:00:00.000Z"
},
"adp": [
{
"problemTypes": [
{
"descriptions": [
{
"type": "CWE",
"cweId": "CWE-287",
"lang": "en",
"description": "CWE-287 Improper Authentication"
}
]
}
],
"affected": [
{
"vendor": "sannce",
"product": "smart_hd_wifi_security_camera_ean_2_950004_595317_firmware",
"cpes": [
"cpe:2.3:o:sannce:smart_hd_wifi_security_camera_ean_2_950004_595317_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"versions": [
{
"version": "0",
"status": "affected"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
}
},
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2024-07-30T14:24:26.869059Z",
"id": "CVE-2019-20464",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2024-07-30T14:28:13.491Z"
}
},
{
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2024-08-05T02:39:10.022Z"
},
"title": "CVE Program Container",
"references": [
{
"url": "https://www.eurofins-cybersecurity.com/news/connected-devices-baby-monitors-part-2/",
"tags": [
"x_transferred"
]
},
{
"name": "20240729 Bunch of IoT CVEs",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "http://seclists.org/fulldisclosure/2024/Jul/14"
}
]
}
]
},
"dataVersion": "5.1"
}