"affected": [
|
|
{
|
|
"product": "Cisco Small Business 220 Series Smart Plus Switches",
|
|
"vendor": "Cisco",
|
|
"versions": [
|
|
{
|
|
"lessThan": "1.1.4.4",
|
|
"status": "affected",
|
|
"version": "unspecified",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"datePublic": "2019-08-06T00:00:00.000Z",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A vulnerability in the web management interface of Cisco Small Business 220 Series Smart Switches could allow an authenticated, remote attacker to perform a command injection attack. The vulnerability is due to insufficient validation of user-supplied input. An attacker could exploit this vulnerability by sending a malicious request to certain parts of the web management interface. To send the malicious request, the attacker needs a valid login session in the web management interface as a privilege level 15 user. Depending on the configuration of the affected switch, the malicious request must be sent via HTTP or HTTPS. A successful exploit could allow the attacker to execute arbitrary shell commands with the privileges of the root user."
|
|
}
|
|
],
|
|
"exploits": [
|
|
{
|
|
"lang": "en",
|
|
"value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
|
|
}
|
|
],
|
|
"metrics": [
|
|
{
|
|
"cvssV3_0": {
|
|
"attackComplexity": "LOW",
|
|
"attackVector": "NETWORK",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 7.2,
|
|
"baseSeverity": "HIGH",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"privilegesRequired": "HIGH",
|
|
"scope": "UNCHANGED",
|
|
"userInteraction": "NONE",
|
|
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
|
|
"version": "3.0"
|
|
}
|
|
}
|
|
],
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"cweId": "CWE-20",
|
|
"description": "CWE-20",
|
|
"lang": "en",
|
|
"type": "CWE"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"providerMetadata": {
|
|
"dateUpdated": "2019-10-01T22:06:04.000Z",
|
|
"orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
|
|
"shortName": "cisco"
|
|
},
|
|
"references": [
|
|
{
|
|
"name": "20190806 Cisco Small Business 220 Series Smart Switches Command Injection Vulnerability",
|
|
"tags": [
|
|
"vendor-advisory",
|
|
"x_refsource_CISCO"
|
|
],
|
|
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190806-sb220-inject"
|
|
},
|
|
{
|
|
"tags": [
|
|
"x_refsource_MISC"
|
|
],
|
|
"url": "http://packetstormsecurity.com/files/154667/Realtek-Managed-Switch-Controller-RTL83xx-Stack-Overflow.html"
|
|
}
|
|
],
|
|
"source": {
|
|
"advisory": "cisco-sa-20190806-sb220-inject",
|
|
"defect": [
|
|
[
|
|
"CSCvo66557"
|
|
]
|
|
],
|
|
"discovery": "INTERNAL"
|
|
},
|
|
"title": "Cisco Small Business 220 Series Smart Switches Command Injection Vulnerability",
|
|
"x_legacyV4Record": {
|
|
"CVE_data_meta": {
|
|
"ASSIGNER": "psirt@cisco.com",
|
|
"DATE_PUBLIC": "2019-08-06T14:00:00-0700",
|
|
"ID": "CVE-2019-1914",
|
|
"STATE": "PUBLIC",
|
|
"TITLE": "Cisco Small Business 220 Series Smart Switches Command Injection Vulnerability"
|
|
},
|
|
"affects": {
|
|
"vendor": {
|
|
"vendor_data": [
|
|
{
|
|
"product": {
|
|
"product_data": [
|
|
{
|
|
"product_name": "Cisco Small Business 220 Series Smart Plus Switches",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"affected": "<",
|
|
"version_affected": "<",
|
|
"version_value": "1.1.4.4"
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
},
|
|
"vendor_name": "Cisco"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
"data_format": "MITRE",
|
|
"data_type": "CVE",
|
|
"data_version": "4.0",
|
|
"description": {
|
|
"description_data": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "A vulnerability in the web management interface of Cisco Small Business 220 Series Smart Switches could allow an authenticated, remote attacker to perform a command injection attack. The vulnerability is due to insufficient validation of user-supplied input. An attacker could exploit this vulnerability by sending a malicious request to certain parts of the web management interface. To send the malicious request, the attacker needs a valid login session in the web management interface as a privilege level 15 user. Depending on the configuration of the affected switch, the malicious request must be sent via HTTP or HTTPS. A successful exploit could allow the attacker to execute arbitrary shell commands with the privileges of the root user."
|
|
}
|
|
]
|
|
},
|
|
"exploit": [
|
|
{
|
|
"lang": "en",
|
|
"value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
|
|
}
|
|
],
|
|
"impact": {
|
|
"cvss": {
|
|
"baseScore": "7.2",
|
|
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
|
|
"version": "3.0"
|
|
}
|
|
},
|
|
"problemtype": {
|
|
"problemtype_data": [
|
|
{
|
|
"description": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "CWE-20"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"references": {
|
|
"reference_data": [
|
|
{
|
|
"name": "20190806 Cisco Small Business 220 Series Smart Switches Command Injection Vulnerability",
|
|
"refsource": "CISCO",
|
|
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190806-sb220-inject"
|
|
},
|
|
{
|
|
"name": "http://packetstormsecurity.com/files/154667/Realtek-Managed-Switch-Controller-RTL83xx-Stack-Overflow.html",
|
|
"refsource": "MISC",
|
|
"url": "http://packetstormsecurity.com/files/154667/Realtek-Managed-Switch-Controller-RTL83xx-Stack-Overflow.html"
|
|
}
|
|
]
|
|
},
|
|
"source": {
|
|
"advisory": "cisco-sa-20190806-sb220-inject",
|
|
"defect": [
|
|
[
|
|
"CSCvo66557"
|
|
]
|
|
],
|
|
"discovery": "INTERNAL"
|
|
}
|
|
}
|
|
},
|
|
"adp": [
|
|
{
|
|
"providerMetadata": {
|
|
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"shortName": "CVE",
|
|
"dateUpdated": "2024-08-04T18:35:50.766Z"
|
|
},
|
|
"title": "CVE Program Container",
|
|
"references": [
|
|
{
|
|
"name": "20190806 Cisco Small Business 220 Series Smart Switches Command Injection Vulnerability",
|
|
"tags": [
|
|
"vendor-advisory",
|
|
"x_refsource_CISCO",
|
|
"x_transferred"
|
|
],
|
|
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190806-sb220-inject"
|
|
},
|
|
{
|
|
"tags": [
|
|
"x_refsource_MISC",
|
|
"x_transferred"
|
|
],
|
|
"url": "http://packetstormsecurity.com/files/154667/Realtek-Managed-Switch-Controller-RTL83xx-Stack-Overflow.html"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"metrics": [
|
|
{
|
|
"other": {
|
|
"type": "ssvc",
|
|
"content": {
|
|
"timestamp": "2024-11-20T16:53:42.707370Z",
|
|
"id": "CVE-2019-1914",
|
|
"options": [
|
|
{
|
|
"Exploitation": "none"
|
|
},
|
|
{
|
|
"Automatable": "no"
|
|
},
|
|
{
|
|
"Technical Impact": "total"
|
|
}
|
|
],
|
|
"role": "CISA Coordinator",
|
|
"version": "2.0.3"
|
|
}
|
|
}
|
|
}
|
|
],
|
|
"title": "CISA ADP Vulnrichment",
|
|
"providerMetadata": {
|
|
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
|
"shortName": "CISA-ADP",
|
|
"dateUpdated": "2024-11-20T17:14:57.430Z"
|
|
}
|
|
}
|
|
]
|
|
},
|
|
"cveMetadata": {
|
|
"assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
|
|
"assignerShortName": "cisco",
|
|
"cveId": "CVE-2019-1914",
|
|
"datePublished": "2019-08-07T05:50:11.911Z",
|
|
"dateReserved": "2018-12-06T00:00:00.000Z",
|
|
"dateUpdated": "2024-11-20T17:14:57.430Z",
|
|
"state": "PUBLISHED"
|
|
},
|
|
"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.1"
|
|
} |