Files
vuln-cve/data/2019/11xxx/CVE-2019-11602.json
T

204 lines
7.8 KiB
JSON

{
"containers": {
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Philip Kazmeier"
}
],
"datePublic": "2019-08-19T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Leakage of stack traces in remote access to backup & restore in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.2.0 allows remote attackers to gather information about the file system structure."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-08-21T19:21:38.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
}
],
"source": {
"advisory": "BOSCH-SA-562575",
"discovery": "EXTERNAL"
},
"title": "Leakage of stack traces in the backup & restore functionality of ProSyst mBS SDK and Bosch IoT Gateway Software",
"x_generator": {
"engine": "Vulnogram 0.0.7"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"DATE_PUBLIC": "2019-08-19T00:00:00.000Z",
"ID": "CVE-2019-11602",
"STATE": "PUBLIC",
"TITLE": "Leakage of stack traces in the backup & restore functionality of ProSyst mBS SDK and Bosch IoT Gateway Software"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Philip Kazmeier"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Leakage of stack traces in remote access to backup & restore in earlier versions than ProSyst mBS SDK 8.2.6 and Bosch IoT Gateway Software 9.2.0 allows remote attackers to gather information about the file system structure."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.7"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html",
"refsource": "CONFIRM",
"url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
}
]
},
"source": {
"advisory": "BOSCH-SA-562575",
"discovery": "EXTERNAL"
}
}
},
"adp": [
{
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2024-08-04T22:55:41.050Z"
},
"title": "CVE Program Container",
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://psirt.bosch.com/Advisory/BOSCH-SA-562575.html"
}
]
}
]
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-11602",
"datePublished": "2019-08-21T19:21:38.452Z",
"dateReserved": "2019-04-30T00:00:00.000Z",
"dateUpdated": "2024-09-17T00:56:40.970Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}