"containers": {
|
|
"cna": {
|
|
"affected": [
|
|
{
|
|
"product": "FactoryTalk Activation",
|
|
"vendor": "Rockwell Automation",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "FactoryTalk Activation Service, Version 4.00.02 and prior versions."
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"datePublic": "2017-03-21T00:00:00.000Z",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Without quotation marks, any whitespace in the file path for Rockwell Automation FactoryTalk Activation version 4.00.02 remains ambiguous, which may allow an attacker to link to or run a malicious executable. This may allow an authorized, but not privileged local user to execute arbitrary code with elevated privileges on the system. CVSS v3 base score: 8.8, CVSS vector string: (AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H). Rockwell Automation has released a new version of FactoryTalk Activation, Version 4.01, which addresses the identified vulnerability. Rockwell Automation recommends upgrading to the latest version of FactoryTalk Activation, Version 4.01 or later."
|
|
}
|
|
],
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"cweId": "CWE-428",
|
|
"description": "Unquoted search path or element CWE-428",
|
|
"lang": "en",
|
|
"type": "CWE"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"providerMetadata": {
|
|
"dateUpdated": "2018-05-12T09:57:01.000Z",
|
|
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
|
|
"shortName": "icscert"
|
|
},
|
|
"references": [
|
|
{
|
|
"name": "96996",
|
|
"tags": [
|
|
"vdb-entry",
|
|
"x_refsource_BID"
|
|
],
|
|
"url": "http://www.securityfocus.com/bid/96996"
|
|
},
|
|
{
|
|
"tags": [
|
|
"x_refsource_MISC"
|
|
],
|
|
"url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/939382"
|
|
},
|
|
{
|
|
"tags": [
|
|
"x_refsource_MISC"
|
|
],
|
|
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-047-02"
|
|
}
|
|
],
|
|
"x_legacyV4Record": {
|
|
"CVE_data_meta": {
|
|
"ASSIGNER": "ics-cert@hq.dhs.gov",
|
|
"DATE_PUBLIC": "2017-03-21T00:00:00",
|
|
"ID": "CVE-2017-6015",
|
|
"STATE": "PUBLIC"
|
|
},
|
|
"affects": {
|
|
"vendor": {
|
|
"vendor_data": [
|
|
{
|
|
"product": {
|
|
"product_data": [
|
|
{
|
|
"product_name": "FactoryTalk Activation",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_value": "FactoryTalk Activation Service, Version 4.00.02 and prior versions."
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
},
|
|
"vendor_name": "Rockwell Automation"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
"data_format": "MITRE",
|
|
"data_type": "CVE",
|
|
"data_version": "4.0",
|
|
"description": {
|
|
"description_data": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "Without quotation marks, any whitespace in the file path for Rockwell Automation FactoryTalk Activation version 4.00.02 remains ambiguous, which may allow an attacker to link to or run a malicious executable. This may allow an authorized, but not privileged local user to execute arbitrary code with elevated privileges on the system. CVSS v3 base score: 8.8, CVSS vector string: (AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H). Rockwell Automation has released a new version of FactoryTalk Activation, Version 4.01, which addresses the identified vulnerability. Rockwell Automation recommends upgrading to the latest version of FactoryTalk Activation, Version 4.01 or later."
|
|
}
|
|
]
|
|
},
|
|
"problemtype": {
|
|
"problemtype_data": [
|
|
{
|
|
"description": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "Unquoted search path or element CWE-428"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"references": {
|
|
"reference_data": [
|
|
{
|
|
"name": "96996",
|
|
"refsource": "BID",
|
|
"url": "http://www.securityfocus.com/bid/96996"
|
|
},
|
|
{
|
|
"name": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/939382",
|
|
"refsource": "MISC",
|
|
"url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/939382"
|
|
},
|
|
{
|
|
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-047-02",
|
|
"refsource": "MISC",
|
|
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-047-02"
|
|
}
|
|
]
|
|
}
|
|
}
|
|
},
|
|
"adp": [
|
|
{
|
|
"providerMetadata": {
|
|
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"shortName": "CVE",
|
|
"dateUpdated": "2024-08-05T15:18:49.328Z"
|
|
},
|
|
"title": "CVE Program Container",
|
|
"references": [
|
|
{
|
|
"name": "96996",
|
|
"tags": [
|
|
"vdb-entry",
|
|
"x_refsource_BID",
|
|
"x_transferred"
|
|
],
|
|
"url": "http://www.securityfocus.com/bid/96996"
|
|
},
|
|
{
|
|
"tags": [
|
|
"x_refsource_MISC",
|
|
"x_transferred"
|
|
],
|
|
"url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/939382"
|
|
},
|
|
{
|
|
"tags": [
|
|
"x_refsource_MISC",
|
|
"x_transferred"
|
|
],
|
|
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-047-02"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"cveMetadata": {
|
|
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
|
|
"assignerShortName": "icscert",
|
|
"cveId": "CVE-2017-6015",
|
|
"datePublished": "2018-05-11T13:00:00.000Z",
|
|
"dateReserved": "2017-02-16T00:00:00.000Z",
|
|
"dateUpdated": "2024-09-16T21:07:54.228Z",
|
|
"state": "PUBLISHED"
|
|
},
|
|
"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.1"
|
|
} |