{ "containers": { "cna": { "providerMetadata": { "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens", "dateUpdated": "2024-07-09T12:03:53.948Z" }, "descriptions": [ { "lang": "en", "value": "Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually." } ], "affected": [ { "vendor": "Siemens", "product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller", "versions": [ { "status": "affected", "version": "All versions < V4.1.1 Patch 05" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200", "versions": [ { "status": "affected", "version": "All versions < V4.5" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P", "versions": [ { "status": "affected", "version": "All versions < V4.5" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC Compact Field Unit", "versions": [ { "status": "affected", "version": "All versions" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC ET 200AL IM 157-1 PN", "versions": [ { "status": "affected", "version": "0", "lessThan": "V1.0.2", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC ET 200M (incl. SIPLUS variants)", "versions": [ { "status": "affected", "version": "All versions" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC ET 200MP IM 155-5 PN BA", "versions": [ { "status": "affected", "version": "0", "lessThan": "V4.0.2", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC ET 200MP IM 155-5 PN HF", "versions": [ { "status": "affected", "version": "0", "lessThan": "V4.2.0", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC ET 200MP IM 155-5 PN ST", "versions": [ { "status": "affected", "version": "0", "lessThan": "V4.1.0", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC ET 200pro IM 154-3 PN HF", "versions": [ { "status": "affected", "version": "0", "lessThan": "*", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC ET 200pro IM 154-4 PN HF", "versions": [ { "status": "affected", "version": "0", "lessThan": "*", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC ET 200SP IM 155-6 PN BA", "versions": [ { "status": "affected", "version": "0", "lessThan": "*", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)", "versions": [ { "status": "affected", "version": "All versions < V1.1.0" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC ET 200SP IM 155-6 PN HF", "versions": [ { "status": "affected", "version": "0", "lessThan": "V4.2.0", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC ET 200SP IM 155-6 PN HS", "versions": [ { "status": "affected", "version": "0", "lessThan": "V4.0.1", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC ET 200SP IM 155-6 PN ST", "versions": [ { "status": "affected", "version": "0", "lessThan": "*", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC ET 200SP IM 155-6 PN ST", "versions": [ { "status": "affected", "version": "0", "lessThan": "*", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC ET 200SP IM 155-6 PN ST BA", "versions": [ { "status": "affected", "version": "0", "lessThan": "*", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC ET 200SP IM 155-6 PN ST BA", "versions": [ { "status": "affected", "version": "0", "lessThan": "*", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12", "versions": [ { "status": "affected", "version": "All versions" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12", "versions": [ { "status": "affected", "version": "All versions" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC ET200ecoPN, 4AO U/I 4xM12", "versions": [ { "status": "affected", "version": "All versions" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12", "versions": [ { "status": "affected", "version": "All versions" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12", "versions": [ { "status": "affected", "version": "All versions" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12", "versions": [ { "status": "affected", "version": "All versions" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12", "versions": [ { "status": "affected", "version": "All versions" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12", "versions": [ { "status": "affected", "version": "All versions" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12", "versions": [ { "status": "affected", "version": "All versions" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12", "versions": [ { "status": "affected", "version": "All versions" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12", "versions": [ { "status": "affected", "version": "All versions" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12", "versions": [ { "status": "affected", "version": "All versions" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC ET200ecoPN: IO-Link Master", "versions": [ { "status": "affected", "version": "All versions" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC ET200S (incl. SIPLUS variants)", "versions": [ { "status": "affected", "version": "All versions" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)", "versions": [ { "status": "affected", "version": "All versions < V4.2.0" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)", "versions": [ { "status": "affected", "version": "All versions < V4.2.3" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "versions": [ { "status": "affected", "version": "All versions < V2.0" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC S7-1500 Software Controller", "versions": [ { "status": "affected", "version": "All versions < V2.0" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC S7-200 SMART", "versions": [ { "status": "affected", "version": "All versions < V2.03.01" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "versions": [ { "status": "affected", "version": "0", "lessThan": "V3.X.16", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC S7-400 H V6 and below CPU family (incl. SIPLUS variants)", "versions": [ { "status": "affected", "version": "0", "lessThan": "V6.0.8", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)", "versions": [ { "status": "affected", "version": "0", "lessThan": "V6.0.6", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)", "versions": [ { "status": "affected", "version": "0", "lessThan": "V7.0.2", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)", "versions": [ { "status": "affected", "version": "All versions < V8.2.1" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC TDC CP51M1", "versions": [ { "status": "affected", "version": "0", "lessThan": "V1.1.8", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC TDC CPU555", "versions": [ { "status": "affected", "version": "0", "lessThan": "V1.1.1", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC WinAC RTX 2010", "versions": [ { "status": "affected", "version": "All versions < V2010 SP3" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMATIC WinAC RTX F 2010", "versions": [ { "status": "affected", "version": "All versions < V2010 SP3" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)", "versions": [ { "status": "affected", "version": "All versions < V2.1.1" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMOTION C", "versions": [ { "status": "affected", "version": "All versions < V5.1 HF1" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMOTION D", "versions": [ { "status": "affected", "version": "All versions < V5.1 HF1" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants)", "versions": [ { "status": "affected", "version": "All versions < V4.4 HF26" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMOTION P V4.4 and V4.5", "versions": [ { "status": "affected", "version": "All versions < V4.5 HF5" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIMOTION P V5", "versions": [ { "status": "affected", "version": "All versions < V5.1 HF1" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SINAMICS DCM w. PN", "versions": [ { "status": "affected", "version": "All versions < V1.4 SP1 HF6" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SINAMICS DCP w. PN", "versions": [ { "status": "affected", "version": "All versions < V1.2 HF2" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SINAMICS G110M w. PN", "versions": [ { "status": "affected", "version": "All versions < V4.7 SP9 HF1" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)", "versions": [ { "status": "affected", "version": "All versions < V4.7 SP9 HF1" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SINAMICS G130 V4.7 w. PN", "versions": [ { "status": "affected", "version": "All versions < V4.7 HF29" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SINAMICS G130 V4.8 w. PN", "versions": [ { "status": "affected", "version": "All versions < V4.8 HF4" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SINAMICS G150 V4.7 w. PN", "versions": [ { "status": "affected", "version": "All versions < V4.7 HF29" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SINAMICS G150 V4.8 w. PN", "versions": [ { "status": "affected", "version": "All versions < V4.8 HF4" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SINAMICS GH150 V4.7 w. PROFINET", "versions": [ { "status": "affected", "version": "All versions < V4.7 SP5 HF7" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SINAMICS GL150 V4.7 w. PROFINET", "versions": [ { "status": "affected", "version": "All versions < V4.8 SP2" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SINAMICS GM150 V4.7 w. PROFINET", "versions": [ { "status": "affected", "version": "All versions < V4.7 HF31" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SINAMICS S110 w. PN", "versions": [ { "status": "affected", "version": "All versions < V4.4 SP3 HF6" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)", "versions": [ { "status": "affected", "version": "All versions < V4.7" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)", "versions": [ { "status": "affected", "version": "All versions" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)", "versions": [ { "status": "affected", "version": "All versions < V4.7 HF29" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)", "versions": [ { "status": "affected", "version": "All versions < V4.8 HF5" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SINAMICS S150 V4.7 w. PN", "versions": [ { "status": "affected", "version": "All versions < V4.7 HF29" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SINAMICS S150 V4.8 w. PN", "versions": [ { "status": "affected", "version": "All versions < V4.8 HF4" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SINAMICS SL150 V4.7.0 w. PROFINET", "versions": [ { "status": "affected", "version": "All versions < V4.7 HF30" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SINAMICS SL150 V4.7.4 w. PROFINET", "versions": [ { "status": "affected", "version": "All versions < V4.8 SP2" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SINAMICS SL150 V4.7.5 w. PROFINET", "versions": [ { "status": "affected", "version": "All versions < V4.8 SP2" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SINAMICS SM120 V4.7 w. PROFINET", "versions": [ { "status": "affected", "version": "All versions < V4.8 SP2" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SINAMICS V90 w. PN", "versions": [ { "status": "affected", "version": "All versions < V1.02" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SINUMERIK 840D sl", "versions": [ { "status": "affected", "version": "All versions < V4.8 SP3" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "versions": [ { "status": "affected", "version": "0", "lessThan": "V4.2.0", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "versions": [ { "status": "affected", "version": "0", "lessThan": "V4.2.0", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL", "versions": [ { "status": "affected", "version": "0", "lessThan": "V4.2.0", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIPLUS ET 200MP IM 155-5 PN ST", "versions": [ { "status": "affected", "version": "0", "lessThan": "V4.1.0", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL", "versions": [ { "status": "affected", "version": "0", "lessThan": "V4.1.0", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "versions": [ { "status": "affected", "version": "0", "lessThan": "V4.2.0", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "versions": [ { "status": "affected", "version": "0", "lessThan": "V4.2.0", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL", "versions": [ { "status": "affected", "version": "0", "lessThan": "V4.2.0", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIPLUS ET 200SP IM 155-6 PN ST", "versions": [ { "status": "affected", "version": "0", "lessThan": "*", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIPLUS ET 200SP IM 155-6 PN ST", "versions": [ { "status": "affected", "version": "0", "lessThan": "*", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA", "versions": [ { "status": "affected", "version": "0", "lessThan": "*", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA", "versions": [ { "status": "affected", "version": "0", "lessThan": "*", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL", "versions": [ { "status": "affected", "version": "0", "lessThan": "*", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL", "versions": [ { "status": "affected", "version": "0", "lessThan": "*", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL", "versions": [ { "status": "affected", "version": "0", "lessThan": "*", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL", "versions": [ { "status": "affected", "version": "0", "lessThan": "*", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "SIRIUS Soft Starter 3RW44 PN", "versions": [ { "status": "affected", "version": "All versions" } ], "defaultStatus": "unknown" } ], "metrics": [ { "cvssV3_1": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "baseScore": 7.5, "baseSeverity": "HIGH" } }, { "cvssV4_0": { "version": "4.0", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "baseScore": 8.7, "baseSeverity": "HIGH" } } ], "problemTypes": [ { "descriptions": [ { "lang": "en", "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "type": "CWE" } ] } ], "references": [ { "name": "101964", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "https://www.securityfocus.com/bid/101964" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-346262.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-141614.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-346262.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-141614.html" } ] }, "adp": [ { "providerMetadata": { "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-05T18:51:06.315Z" }, "title": "CVE Program Container", "references": [ { "name": "101964", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "https://www.securityfocus.com/bid/101964" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-346262.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-141614.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-346262.html", "tags": [ "x_transferred" ] }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html", "tags": [ "x_transferred" ] }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-141614.html", "tags": [ "x_transferred" ] } ] } ] }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2017-12741", "datePublished": "2017-12-26T04:00:00.000Z", "dateReserved": "2017-08-09T00:00:00.000Z", "dateUpdated": "2024-08-05T18:51:06.315Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }