{ "containers": { "cna": { "affected": [ { "product": "Trend Micro Encryption for Email", "vendor": "Trend Micro", "versions": [ { "status": "affected", "version": "5.6" } ] } ], "datePublic": "2017-11-17T00:00:00.000Z", "descriptions": [ { "lang": "en", "value": "A service DLL preloading vulnerability in Trend Micro Encryption for Email versions 5.6 and below could allow an unauthenticated remote attacker to execute arbitrary code on a vulnerable system." } ], "problemTypes": [ { "descriptions": [ { "description": "OTHER - DLL Preloacding vulnerability", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2017-12-15T13:57:01.000Z", "orgId": "7f7bd7df-cffe-4fdb-ab6d-859363b89272", "shortName": "trendmicro" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://success.trendmicro.com/solution/1118796" }, { "tags": [ "x_refsource_MISC" ], "url": "https://fortiguard.com/zeroday/FG-VD-17-079" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "security@trendmicro.com", "ID": "CVE-2017-11397", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Trend Micro Encryption for Email", "version": { "version_data": [ { "version_value": "5.6" } ] } } ] }, "vendor_name": "Trend Micro" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A service DLL preloading vulnerability in Trend Micro Encryption for Email versions 5.6 and below could allow an unauthenticated remote attacker to execute arbitrary code on a vulnerable system." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "OTHER - DLL Preloacding vulnerability" } ] } ] }, "references": { "reference_data": [ { "name": "https://success.trendmicro.com/solution/1118796", "refsource": "CONFIRM", "url": "https://success.trendmicro.com/solution/1118796" }, { "name": "https://fortiguard.com/zeroday/FG-VD-17-079", "refsource": "MISC", "url": "https://fortiguard.com/zeroday/FG-VD-17-079" } ] } } }, "adp": [ { "providerMetadata": { "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-05T18:05:30.601Z" }, "title": "CVE Program Container", "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://success.trendmicro.com/solution/1118796" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://fortiguard.com/zeroday/FG-VD-17-079" } ] } ] }, "cveMetadata": { "assignerOrgId": "7f7bd7df-cffe-4fdb-ab6d-859363b89272", "assignerShortName": "trendmicro", "cveId": "CVE-2017-11397", "datePublished": "2017-12-15T14:00:00.000Z", "dateReserved": "2017-07-17T00:00:00.000Z", "dateUpdated": "2024-08-05T18:05:30.601Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }