CVE sync 2026-11-13T22:30:43Z

This commit is contained in:
Vulnerability Bot committed 2026-11-13 23:30:48 +01:00
1 parent aa65f0c147
commit c1444140e5
61 files changed
+6438 -713

No files matched your search

+48 -2
View File
@@ -8,7 +8,7 @@
"assignerShortName": "jci",
"dateReserved": "2025-04-17T20:07:25.121Z",
"datePublished": "2026-11-13T20:14:16.172Z",
"dateUpdated": "2026-11-13T20:14:16.172Z"
"dateUpdated": "2026-11-13T21:27:33.159Z"
},
"containers": {
"cna": {
@@ -157,6 +157,52 @@
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"adp": [
{
"problemTypes": [
{
"descriptions": [
{
"type": "CWE",
"cweId": "CWE-1395",
"lang": "en",
"description": "CWE-1395 Dependency on Vulnerable Third-Party Component"
}
]
}
],
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2026-11-13T21:23:26.021386Z",
"id": "CVE-2025-43867",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2026-11-13T21:27:33.159Z"
}
}
]
}
}
+238
View File
@@ -0,0 +1,238 @@
{
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"cveMetadata": {
"cveId": "CVE-2025-43874",
"assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
"state": "PUBLISHED",
"assignerShortName": "jci",
"dateReserved": "2025-04-17T20:07:25.122Z",
"datePublished": "2026-11-13T21:59:57.409Z",
"dateUpdated": "2026-11-13T21:59:57.409Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
"shortName": "jci",
"dateUpdated": "2026-11-13T21:59:57.409Z"
},
"problemTypes": [
{
"descriptions": [
{
"lang": "en",
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command",
"type": "CWE"
}
]
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88: OS Command Injection"
}
]
}
],
"affected": [
{
"vendor": "Johnson Controls",
"product": "iSTAR Ultra",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "6.9.2.CU02",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Johnson Controls",
"product": "iSTAR Ultra SE",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "6.9.2.CU02",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Johnson Controls",
"product": "iSTAR Ultra G2",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "6.9.2.CU02",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Johnson Controls",
"product": "iSTAR Ultra G2 SE",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "6.9.2.CU02",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Johnson Controls",
"product": "iSTAR Edge G2",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "6.9.2.CU02",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
}
],
"cpeApplicability": [
{
"operator": "OR",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:johnson_controls:istar_ultra:*:*:*:*:*:*:*:*",
"versionStartIncluding": "0",
"versionEndExcluding": "6.9.2.cu02"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:johnson_controls:istar_ultra_se:*:*:*:*:*:*:*:*",
"versionStartIncluding": "0",
"versionEndExcluding": "6.9.2.cu02"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:johnson_controls:istar_ultra_g2:*:*:*:*:*:*:*:*",
"versionStartIncluding": "0",
"versionEndExcluding": "6.9.2.cu02"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:johnson_controls:istar_ultra_g2_se:*:*:*:*:*:*:*:*",
"versionStartIncluding": "0",
"versionEndExcluding": "6.9.2.cu02"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:johnson_controls:istar_edge_g2:*:*:*:*:*:*:*:*",
"versionStartIncluding": "0",
"versionEndExcluding": "6.9.2.cu02"
}
]
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": ": Improper Neutralization of Special Elements used in an OS Command vulnerability in Johnson Controls iSTAR Ultra, Johnson Controls iSTAR Ultra SE, Johnson Controls iSTAR Ultra G2, Johnson Controls iSTAR Ultra G2 SE, and Johnson Controls iSTAR Edge G2 allows : OS Command Injection.\n\nThis issue affects iSTAR Ultra: before 6.9.2.CU02; iSTAR Ultra SE: before 6.9.2.CU02; iSTAR Ultra G2: before 6.9.2.CU02; iSTAR Ultra G2 SE: before 6.9.2.CU02; iSTAR Edge G2: before 6.9.2.CU02.",
"supportingMedia": [
{
"type": "text/html",
"base64": false,
"value": ": Improper Neutralization of Special Elements used in an OS Command vulnerability in Johnson Controls iSTAR Ultra, Johnson Controls iSTAR Ultra SE, Johnson Controls iSTAR Ultra G2, Johnson Controls iSTAR Ultra G2 SE, and Johnson Controls iSTAR Edge G2 allows : OS Command Injection.<p>This issue affects iSTAR Ultra: before 6.9.2.CU02; iSTAR Ultra SE: before 6.9.2.CU02; iSTAR Ultra G2: before 6.9.2.CU02; iSTAR Ultra G2 SE: before 6.9.2.CU02; iSTAR Edge G2: before 6.9.2.CU02.</p>"
}
]
}
],
"references": [
{
"url": "https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories"
}
],
"metrics": [
{
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
],
"cvssV4_0": {
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"vulnConfidentialityImpact": "HIGH",
"subConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"subIntegrityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"subAvailabilityImpact": "NONE",
"exploitMaturity": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"version": "4.0",
"baseSeverity": "HIGH",
"baseScore": 8.7,
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N"
}
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
}
}
+237
View File
@@ -0,0 +1,237 @@
{
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"cveMetadata": {
"cveId": "CVE-2025-53697",
"assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
"state": "PUBLISHED",
"assignerShortName": "jci",
"dateReserved": "2025-07-08T14:48:42.604Z",
"datePublished": "2026-11-13T21:37:44.321Z",
"dateUpdated": "2026-11-13T21:41:47.141Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
"shortName": "jci",
"dateUpdated": "2026-11-13T21:41:47.141Z"
},
"problemTypes": [
{
"descriptions": [
{
"lang": "en",
"cweId": "CWE-1392",
"description": "CWE-1392 Use of default credentials",
"type": "CWE"
}
]
}
],
"impacts": [
{
"descriptions": [
{
"lang": "en",
"value": "CAPEC‑560: Use of Default Credentials"
}
]
}
],
"affected": [
{
"vendor": "Johnson Controls",
"product": "iSTAR Ultra",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "2.9.2.CU02",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Johnson Controls",
"product": "iSTAR Ultra SE",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "6.9.2.CU02",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Johnson Controls",
"product": "iSTAR Ultra G2",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "6.9.2.CU02",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Johnson Controls",
"product": "iSTAR Ultra G2 SE",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "6.9.2.CU02",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Johnson Controls",
"product": "iSTAR Edge G2",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "6.9.2.CU02",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
}
],
"cpeApplicability": [
{
"operator": "OR",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:johnson_controls:istar_ultra:*:*:*:*:*:*:*:*",
"versionStartIncluding": "0",
"versionEndExcluding": "2.9.2.cu02"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:johnson_controls:istar_ultra_se:*:*:*:*:*:*:*:*",
"versionStartIncluding": "0",
"versionEndExcluding": "6.9.2.cu02"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:johnson_controls:istar_ultra_g2:*:*:*:*:*:*:*:*",
"versionStartIncluding": "0",
"versionEndExcluding": "6.9.2.cu02"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:johnson_controls:istar_ultra_g2_se:*:*:*:*:*:*:*:*",
"versionStartIncluding": "0",
"versionEndExcluding": "6.9.2.cu02"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:johnson_controls:istar_edge_g2:*:*:*:*:*:*:*:*",
"versionStartIncluding": "0",
"versionEndExcluding": "6.9.2.cu02"
}
]
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Use of default credentials vulnerability in Johnson Controls iSTAR Ultra, Johnson Controls iSTAR Ultra SE, Johnson Controls iSTAR Ultra G2, Johnson Controls iSTAR Ultra G2 SE, and Johnson Controls iSTAR Edge G2 allows CAPEC‑560: Use of Default Credentials.\n\nThis issue affects iSTAR Ultra: before 2.9.2.CU02; iSTAR Ultra SE: before 6.9.2.CU02; iSTAR Ultra G2: before 6.9.2.CU02; iSTAR Ultra G2 SE: before 6.9.2.CU02; iSTAR Edge G2: before 6.9.2.CU02.",
"supportingMedia": [
{
"type": "text/html",
"base64": false,
"value": "Use of default credentials vulnerability in Johnson Controls iSTAR Ultra, Johnson Controls iSTAR Ultra SE, Johnson Controls iSTAR Ultra G2, Johnson Controls iSTAR Ultra G2 SE, and Johnson Controls iSTAR Edge G2 allows CAPEC‑560: Use of Default Credentials.<p>This issue affects iSTAR Ultra: before 2.9.2.CU02; iSTAR Ultra SE: before 6.9.2.CU02; iSTAR Ultra G2: before 6.9.2.CU02; iSTAR Ultra G2 SE: before 6.9.2.CU02; iSTAR Edge G2: before 6.9.2.CU02.</p>"
}
]
}
],
"references": [
{
"url": "https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories"
}
],
"metrics": [
{
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
],
"cvssV4_0": {
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "HIGH",
"userInteraction": "NONE",
"vulnConfidentialityImpact": "HIGH",
"subConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"subIntegrityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"subAvailabilityImpact": "NONE",
"exploitMaturity": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"version": "4.0",
"baseSeverity": "HIGH",
"baseScore": 8.4,
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N"
}
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
}
}
+162
View File
@@ -0,0 +1,162 @@
{
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"cveMetadata": {
"cveId": "CVE-2025-53698",
"assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
"state": "PUBLISHED",
"assignerShortName": "jci",
"dateReserved": "2025-07-08T14:48:42.604Z",
"datePublished": "2026-11-13T21:46:48.829Z",
"dateUpdated": "2026-11-13T21:46:48.829Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
"shortName": "jci",
"dateUpdated": "2026-11-13T21:46:48.829Z"
},
"problemTypes": [
{
"descriptions": [
{
"lang": "en",
"cweId": "CWE-1299",
"description": "CWE-1299 Missing protection mechanism for alternate hardware interface",
"type": "CWE"
}
]
}
],
"impacts": [
{
"descriptions": [
{
"lang": "en",
"value": "CAPEC‑554: Functionality Bypass"
}
]
}
],
"affected": [
{
"vendor": "Johnson Controls",
"product": "iSTAR Ultra",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "6.9.2.CU02",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Johnson Controls",
"product": "iSTAR Ultra SE",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "6.9.2.CU02",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
}
],
"cpeApplicability": [
{
"operator": "OR",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:johnson_controls:istar_ultra:*:*:*:*:*:*:*:*",
"versionStartIncluding": "0",
"versionEndExcluding": "6.9.2.cu02"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:johnson_controls:istar_ultra_se:*:*:*:*:*:*:*:*",
"versionStartIncluding": "0",
"versionEndExcluding": "6.9.2.cu02"
}
]
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Missing protection mechanism for alternate hardware interface vulnerability in Johnson Controls iSTAR Ultra and Johnson Controls iSTAR Ultra SE allows CAPEC‑554: Functionality Bypass.\n\nThis issue affects iSTAR Ultra: before 6.9.2.CU02; iSTAR Ultra SE: before 6.9.2.CU02.",
"supportingMedia": [
{
"type": "text/html",
"base64": false,
"value": "Missing protection mechanism for alternate hardware interface vulnerability in Johnson Controls iSTAR Ultra and Johnson Controls iSTAR Ultra SE allows CAPEC‑554: Functionality Bypass.<p>This issue affects iSTAR Ultra: before 6.9.2.CU02; iSTAR Ultra SE: before 6.9.2.CU02.</p>"
}
]
}
],
"references": [
{
"url": "https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories"
}
],
"metrics": [
{
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
],
"cvssV4_0": {
"attackVector": "PHYSICAL",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"vulnConfidentialityImpact": "HIGH",
"subConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"subIntegrityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"subAvailabilityImpact": "NONE",
"exploitMaturity": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"version": "4.0",
"baseSeverity": "HIGH",
"baseScore": 7,
"vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N"
}
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
}
}
+237
View File
@@ -0,0 +1,237 @@
{
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"cveMetadata": {
"cveId": "CVE-2025-53699",
"assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
"state": "PUBLISHED",
"assignerShortName": "jci",
"dateReserved": "2025-07-08T14:48:42.604Z",
"datePublished": "2026-11-13T21:50:56.925Z",
"dateUpdated": "2026-11-13T21:50:56.925Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
"shortName": "jci",
"dateUpdated": "2026-11-13T21:50:56.925Z"
},
"problemTypes": [
{
"descriptions": [
{
"lang": "en",
"cweId": "CWE-1299",
"description": "CWE-1299 Missing protection mechanism for alternate hardware interface",
"type": "CWE"
}
]
}
],
"impacts": [
{
"descriptions": [
{
"lang": "en",
"value": "CAPEC‑554: Functionality Bypass"
}
]
}
],
"affected": [
{
"vendor": "Johnson Controls",
"product": "iSTAR Ultra",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "6.9.2.CU02",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Johnson Controls",
"product": "iSTAR Ultra SE",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "6.9.2.CU02",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Johnson Controls",
"product": "iSTAR Ultra G2",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "6.9.2.CU02",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Johnson Controls",
"product": "iSTAR Ultra G2 SE",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "6.9.2.CU02",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Johnson Controls",
"product": "iSTAR Edge G2",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "6.9.2.CU02",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
}
],
"cpeApplicability": [
{
"operator": "OR",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:johnson_controls:istar_ultra:*:*:*:*:*:*:*:*",
"versionStartIncluding": "0",
"versionEndExcluding": "6.9.2.cu02"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:johnson_controls:istar_ultra_se:*:*:*:*:*:*:*:*",
"versionStartIncluding": "0",
"versionEndExcluding": "6.9.2.cu02"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:johnson_controls:istar_ultra_g2:*:*:*:*:*:*:*:*",
"versionStartIncluding": "0",
"versionEndExcluding": "6.9.2.cu02"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:johnson_controls:istar_ultra_g2_se:*:*:*:*:*:*:*:*",
"versionStartIncluding": "0",
"versionEndExcluding": "6.9.2.cu02"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:johnson_controls:istar_edge_g2:*:*:*:*:*:*:*:*",
"versionStartIncluding": "0",
"versionEndExcluding": "6.9.2.cu02"
}
]
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Missing protection mechanism for alternate hardware interface vulnerability in Johnson Controls iSTAR Ultra, Johnson Controls iSTAR Ultra SE, Johnson Controls iSTAR Ultra G2, Johnson Controls iSTAR Ultra G2 SE, and Johnson Controls iSTAR Edge G2 allows CAPEC‑554: Functionality Bypass.\n\nThis issue affects iSTAR Ultra: before 6.9.2.CU02; iSTAR Ultra SE: before 6.9.2.CU02; iSTAR Ultra G2: before 6.9.2.CU02; iSTAR Ultra G2 SE: before 6.9.2.CU02; iSTAR Edge G2: before 6.9.2.CU02.",
"supportingMedia": [
{
"type": "text/html",
"base64": false,
"value": "Missing protection mechanism for alternate hardware interface vulnerability in Johnson Controls iSTAR Ultra, Johnson Controls iSTAR Ultra SE, Johnson Controls iSTAR Ultra G2, Johnson Controls iSTAR Ultra G2 SE, and Johnson Controls iSTAR Edge G2 allows CAPEC‑554: Functionality Bypass.<p>This issue affects iSTAR Ultra: before 6.9.2.CU02; iSTAR Ultra SE: before 6.9.2.CU02; iSTAR Ultra G2: before 6.9.2.CU02; iSTAR Ultra G2 SE: before 6.9.2.CU02; iSTAR Edge G2: before 6.9.2.CU02.</p>"
}
]
}
],
"references": [
{
"url": "https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories"
}
],
"metrics": [
{
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
],
"cvssV4_0": {
"attackVector": "PHYSICAL",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"vulnConfidentialityImpact": "HIGH",
"subConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"subIntegrityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"subAvailabilityImpact": "NONE",
"exploitMaturity": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"version": "4.0",
"baseSeverity": "HIGH",
"baseScore": 7,
"vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N"
}
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
}
}
+235
View File
@@ -0,0 +1,235 @@
{
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"cveMetadata": {
"cveId": "CVE-2025-53700",
"assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
"state": "PUBLISHED",
"assignerShortName": "jci",
"dateReserved": "2025-07-08T14:48:42.604Z",
"datePublished": "2026-11-13T21:56:12.492Z",
"dateUpdated": "2026-11-13T21:56:12.492Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
"shortName": "jci",
"dateUpdated": "2026-11-13T21:56:12.492Z"
},
"problemTypes": [
{
"descriptions": [
{
"lang": "en",
"description": "CWE‑922 Insecure Storage of Sensitive Information"
}
]
}
],
"impacts": [
{
"descriptions": [
{
"lang": "en",
"value": "CAPEC‑15 File Manipulation"
}
]
}
],
"affected": [
{
"vendor": "Johnson Controls",
"product": "iSTAR Ultra",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "6.9.2.CU02",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Johnson Controls",
"product": "iSTAR Ultra SE",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "6.9.2.CU02",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Johnson Controls",
"product": "iSTAR Ultra G2",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "6.9.2.CU02",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Johnson Controls",
"product": "iSTAR Ultra G2 SE",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "6.9.2.CU02",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Johnson Controls",
"product": "iSTAR Edge G2",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "6.9.2.CU02",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
}
],
"cpeApplicability": [
{
"operator": "OR",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:johnson_controls:istar_ultra:*:*:*:*:*:*:*:*",
"versionStartIncluding": "0",
"versionEndExcluding": "6.9.2.cu02"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:johnson_controls:istar_ultra_se:*:*:*:*:*:*:*:*",
"versionStartIncluding": "0",
"versionEndExcluding": "6.9.2.cu02"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:johnson_controls:istar_ultra_g2:*:*:*:*:*:*:*:*",
"versionStartIncluding": "0",
"versionEndExcluding": "6.9.2.cu02"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:johnson_controls:istar_ultra_g2_se:*:*:*:*:*:*:*:*",
"versionStartIncluding": "0",
"versionEndExcluding": "6.9.2.cu02"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:johnson_controls:istar_edge_g2:*:*:*:*:*:*:*:*",
"versionStartIncluding": "0",
"versionEndExcluding": "6.9.2.cu02"
}
]
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "CWE‑922 Insecure Storage of Sensitive Information vulnerability in Johnson Controls iSTAR Ultra, Johnson Controls iSTAR Ultra SE, Johnson Controls iSTAR Ultra G2, Johnson Controls iSTAR Ultra G2 SE, and Johnson Controls iSTAR Edge G2 allows CAPEC‑15 File Manipulation.\n\nThis issue affects iSTAR Ultra: before 6.9.2.CU02; iSTAR Ultra SE: before 6.9.2.CU02; iSTAR Ultra G2: before 6.9.2.CU02; iSTAR Ultra G2 SE: before 6.9.2.CU02; iSTAR Edge G2: before 6.9.2.CU02.",
"supportingMedia": [
{
"type": "text/html",
"base64": false,
"value": "CWE‑922 Insecure Storage of Sensitive Information vulnerability in Johnson Controls iSTAR Ultra, Johnson Controls iSTAR Ultra SE, Johnson Controls iSTAR Ultra G2, Johnson Controls iSTAR Ultra G2 SE, and Johnson Controls iSTAR Edge G2 allows CAPEC‑15 File Manipulation.<p>This issue affects iSTAR Ultra: before 6.9.2.CU02; iSTAR Ultra SE: before 6.9.2.CU02; iSTAR Ultra G2: before 6.9.2.CU02; iSTAR Ultra G2 SE: before 6.9.2.CU02; iSTAR Edge G2: before 6.9.2.CU02.</p>"
}
]
}
],
"references": [
{
"url": "https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories"
}
],
"metrics": [
{
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
],
"cvssV4_0": {
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"vulnConfidentialityImpact": "NONE",
"subConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"subIntegrityImpact": "HIGH",
"vulnAvailabilityImpact": "NONE",
"subAvailabilityImpact": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"version": "4.0",
"baseSeverity": "MEDIUM",
"baseScore": 6.3,
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:N/SC:H/SI:H/SA:H"
}
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
}
}